Emerson Machinery Health A6500 R Series Operating Manual page 52

System racks
Table of Contents

Advertisement

Installation and Mounting
June 2023
Figure 4-27: Connection example for piezoelectric sensors
x = slot number 1 to 6 (A6500-FR), 1 to 9 (A6500-RR), or 1 to 11 (A6500-SR)
Connect 3-wire piezoelectric sensors
Piezoelectric sensors are generally used to measure bearing vibration.
Figure 4-28
as GE 330400 and GE 330425.
Recommendations
Twisted pair and double screened cables, such as LiYCY-CY.
Connections
Channel 1 sensor signal: Connect the sensor terminal A to XRx1.1 and terminal C to
XRx1.2 .
Channel 1 sensor supply: Connect the sensor terminal B to XRx1.4 and terminal C to
XRx1.3.
Channel 2 sensor signal: Connect the sensor terminal A to XRx2.1 and terminal C to
XRx2.2 .
Channel 2 sensor supply: Connect the sensor terminal B to XRx2.4 and terminal C to
XRx2.3.
52
shows the connection of -24 V DC powered 3-wire piezoelectric sensors such
Operating Manual
MHM-97877
MHM-97877, Rev. 5.07