Download Print this page

Hyundai HYU-AC-NCDCCF00 1 User Manual page 2

Door controller

Advertisement

The Compact Door Controller
Quick Installation Guide
Please read this guide first for correct installation and retain it for
future reference. The information in this guide was current at the
time of publication. However, Hundai reserves the right to make
changes in product design and specifications without prior
notice.
Copyright
All rights reserved. No part of this document may be copied or
reproduced in any form or by any means without the prior
written consent of Hyndai.
Warranty
Limited Warranty. Valid only if primary protection is provided,
mains supply is within limit and protected, and environment
conditions are maintained within product specifications.
Complete warranty statement is available on our website:
2
Know Your Controller
LED Indicator
RF Card
Sensor
Fingerprint
Sensor
What Your Package Contains - DCFX/DCCX
Ÿ
10 Pin Cable Assembly with Strip
Ÿ
Power Adapter 12VDC, 2 Amp
Connector
Ÿ
Mounting Plate
5 Pin Cable Assembly with Strip
Ÿ
Ÿ
Connector
2 Screws 5/25
Ÿ
2 Screw Grips
120 , 1%, 0.25W RS-485
Ÿ
Ÿ
Power Supply Cable with DC
Termination Resistor
Ÿ
Quick Installation Guide (Printed)
Jack
Ÿ
Ethernet Port Cable with RJ45
Warranty Card (Printed)
Ÿ
Ÿ
Plug
What Your Package Contains - RDFX/RDCX
Ÿ
15 Pin CDC Converter Cable
Ÿ
Mounting Plate
Assembly
Ÿ
2 Screws 5/25
Quick Installation Guide (Printed)
Ÿ
Ÿ
2 Screw Grips
Warranty Card (Printed)
Ÿ
Ÿ
15 Pin CDC to CDC Cable
Ÿ
Assembly
WARNING
Installation and servicing should be done only by a qualified technician.
Ÿ
There are no user-serviceable parts inside.
Ÿ
Opening or removing the device cover may result in electric shock or
Ÿ
exposure to other hazards.
Use this product only for the purpose for which it was designed.
Ÿ
Things You Will Need
Environmental Specifications
Operating Temperature Range: -20 to +60 degrees Centigrade
Humidity Range: 5 to 95% RH Non-Condensing
1
Door Controller
Mounting Hook
To External Reader
5
1
GND
Black
RS232 TX
Grey
Rs232 RX
Pink
GND
Black
TMPR NC/NO
Light Blue
1
W DATA1
White
5
W DATA0
Green
Blue
HOLD
4
BEEPER
Yellow
ALARM
Violet
STATUS
Light Brown
Exit Switch
RED LED
Brown
GREEN LED
Orange
Exit
GND
Black
+12VRDR
Red
Panel Lite
1
Reset
RS-485
1
RS-485 A
Blue
RS-485 B
Brown
4
SHLD
Yellow
EXIT SW
White
GND
Black
Reader
1
Black
GND
RS232 TX
Grey
Rs232 RX
Pink
GND
Black
TMPR NC/NO
Light Blue
W DATA1
White
6
W DATA0
Green
HOLD
Blue
BEEPER
Yellow
ALARM
Violet
STATUS
Light Brown
RED LED
Brown
GREEN LED
Orange
GND
Black
Door Controller
+12VRDR
Red
COSEC ARC
1
RS-485 A
Blue
RS-485 B
Brown
7
SHLD
Yellow
+12VRDR
White
GND
Black
Controller
Variants
Here X stands for E/M/I/P where, E = EM Prox, M = Mifare,
I = HID iCLASS, P = HID Prox
DC Power Jack
DC 12V
Power Supply
1
1
PWR GND Black
1
+12VDC IN Red
Using 12VDC of the Door
1
12V/24V
+12V LOCK
1
1
+12V LOCK
GND
+12V LOCK Red
2
RLY NC
GND
RLY COM
EM Lock
GND
2
DOOR STS
Using External Power Supply
GND
1
RLY NC
RLY COM
RLY NC
RLY NO
3
GND
RLY COM
EM Lock
1
1
TX-
TX+ Brown
RX-
3
RX+ Blue
COM1 Green
RJ-45 Plug
COM1
COM2 Yellow
COM2
Ethernet Cable
6
1
7
RS-485
1
Reset
Variants
Weight
Dimension
Weight and Dimensions
0.234kg
DCFE, DCFM, DCFI, DCFP
159x50x39mm
0.154kg
136x50x31mm
DCCE, DCCM, DCCI, DCCP
0.201kg
159x50x39mm
RDFE, RDFM, RDFI, RDFP
0.120kg
136x50x31mm
RDCE, RDCM, RDCI
Red
Black
Black
White
Black
Blue
Brown
Yellow
Light Blue