innovair AMT Series Installation Instructions And Homeowner's Manual
innovair AMT Series Installation Instructions And Homeowner's Manual

innovair AMT Series Installation Instructions And Homeowner's Manual

Low-boy multiposition oil-fired furnace
Table of Contents

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS AND
INSTALLER / SERVICE TECHNICIAN :
USE THE INFORMATION IN THIS MANUAL FOR THE
INSTALLATION AND SERVICING OF THE FURNACE AND
KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE
REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR
FUTURE REFERENCE.
Printed in Canada on PEFC Certified paper
This paper is from sustainably managed
forests and controlled sources
HOMEOWNER'S MANUAL
AMT SERIES
LOW-BOY MULTIPOSITION
OIL-FIRED FURNACE
Models :
AMT098SD
AMT098SV
Use of the AHRI Certified TM Mark indicates a
manufacturer's participation in the program. For
verification of certification for individual
products, go to www.ahridirectory.org.
Attention :
Do not tamper with the unit or its controls.
Call a qualified service technician.
Manufactured by: Dettson Industries Inc
for Innovair Solutions
Sherbrooke, Qc, Canada
www.dettson.com
2023-12
X40186 E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for innovair AMT Series

  • Page 1 INSTALLATION INSTRUCTIONS AND HOMEOWNER’S MANUAL AMT SERIES LOW-BOY MULTIPOSITION OIL-FIRED FURNACE Models : AMT098SD AMT098SV Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. INSTALLER / SERVICE TECHNICIAN :...
  • Page 2: Table Of Contents

    3.3.9 Restart after burner failure ....9 Table of content EMERGENCY HEATING MODE - VARIABLE SPEED MOTOR (ECM) ....9 SAFETY REGULATIONS ....... 3 MAINTENANCE ..........10 SAFETY LABELING AND WARNING CLEANING THE HEAT EXCHANGER . 10 SIGNS 3 CLEANING THE BLOCKED VENT IMPORTANT INFORMATION ....
  • Page 3: Safety Regulations

    1 SAFETY REGULATIONS WARNING Installations and repairs performed by unqualified persons can SAFETY LABELING AND WARNING SIGNS result in hazards to them and to others. Installations must conform to local codes or, in the absence of same, to codes of The words DANGER, WARNING AND CAUTION are used to identify the country having jurisdiction.
  • Page 4: Installation

    2 INSTALLATION Figure 1: Location and dimensions of ventilation air openings in a closet door The unit is shipped with a burner and its controls. It requires a 115VAC power supply to the control panel and thermostat hook-up as shown on the wiring diagram, one or more oil line connections, suitable ductwork and connection to a properly sized vent.
  • Page 5: Installation Of The Burner

    Figure 2: Thermostat Wiring-Heating & Air Conditioning - Position the gasket between the mounting flange and the burner mounting plate. Align the holes in the burner With 4 Speed Motor mounting plate with the studs on the mounting flange and bolt securely in place.
  • Page 6: Factory Built Chimneys

    Before venting this furnace into a chimney, its condition must be Oil furnaces must have an adequate supply of combustion air. It checked and repairs made, if necessary. Also, the chimney lining and is common practice to assume that older homes have sufficient dimensions must conform to local and national codes.
  • Page 7: Ducting

    At the beginning of each heating season or once a year, check the the electronic board and the jumper provided with the BLUE wire complete oil distribution system for leaks. must be used between the “HEAT” and “COOL” terminals. The blower start/stop delays can be adjusted by positioning the DIP Ensure that the tank is full of clean oil.
  • Page 8: Installation Of Accessories

    2.12 3 OPERATION INSTALLATION OF ACCESSORIES START-UP WARNING Electrical shock hazard. Before starting up the unit, be sure to check that the following items comply: Turn OFF electrical power at the fuse box or service panel before The electrical installation, the oil supply system, the venting making any electrical connections and ensure a proper ground system, combustion air supply and ventilation.
  • Page 9: Combustion Check

    Measure the air temperature in the return air plenum; 3.3.3 Combustion Check Measuring the air temperature in the largest trunk coming off the supply air plenum, just outside the range of radiant heat CAUTION from the heat exchanger. 0.3 m (12") from the plenum of the main take-off is usually sufficient;...
  • Page 10: Maintenance

    4 MAINTENANCE CLEANING THE BLOCKED VENT SHUT- OFF DEVICE (BVSO) WARNING For continuous safe operation, the Blocked Vent Shut-off Electrical shock hazard. device (BVSO) must be inspected and maintained annually by a qualified service technician. Turn OFF power and fuel to the furnace before any disassembly or servicing.
  • Page 11: Furnace Information

    5 FURNACE INFORMATION Model: Serial number: Furnace installation date: Service telephone #-Day: Night: Dealer name and address: START-UP RESULTS Nozzle: Pressure: lb/po Burner adjustments: Primary air Fine air Drawer Assembly Smoke scale: (Bacharach) Gross stack temperature: °F Ambient temperature: °F Chimney draft : "...
  • Page 12: Dimensions And Ratings

    6 DIMENSIONS AND RATINGS Table 7: Technical Specifications UNITS WITH 1/3 HP 4-SPD. MOTOR UNITS WITH 1/2 HP ECM MOTOR LOWBOY SERIES 098 RATING AND PERFORMANCE Firing rate (USGPH)* 0.55 0.70 0.55 0.70 Input (BTU/h)* 77 000 98 000 77 000 98 000 55 - 85 Degr.
  • Page 13: Motors

    Table 8: Airflow Data, Models with 1/3 HP PSC motors EXTERNAL STATIC PRESSURE WITH AIR FILTER BLOWER SPEED 0.2" (W.C.) 0.3" (W.C.) 0.4" (W.C.) 0.5" (W.C.) 0.6" (W.C.) 0.7" (W.C.) HIGH 1420 1335 1240 1180 1085 1025 MED-HIGH 1275 1230 1170 1095 1045...
  • Page 14: Dimensions

    Table 10: Minimum clearances from combustible material CLEARANCES RECOMMANDED ACCESS LOCATION APPLICATION (combustible materials) FOR SERVICE FURNACE 2.54 cm (1") 0.6 m (24") SIDES SUPPLY PLENUM WITHIN 6 FEET OF FURNACE 2.54 cm (1") BACK ACCESS PANEL TO BLOWER 10.16 cm (4") 0.6 m (24") FURNACE OR PLENUM 5.08 cm (2")
  • Page 15 Figure 7: Wiring Diagram - 4 Speed Motor (PSC)
  • Page 16 Figure 8: Wiring Diagram - Variable Speed Motor (ECM)
  • Page 17: Components And Parts List

    7 COMPONENTS AND PARTS LIST Figure 9: Parts List - With 4 Speed motor PSC...
  • Page 18: Sped Motor Psc

    Table 11: Part List – With 4 sped motor PSC ITEM PART # DESCRIPTION COMMENTS B03540 HEAT EXCHANGER ASSEMBLY Heat exchanger only J06L002 EXTRUDED JOINT 1/4 X 1/8 X 25' B03570 FLOOR ASSEMBLY B03561 INSIDE WIRE CHANEL B03572 LOWER DIVIDER ASSEMBLY Includes panel, 3 gaskets and baffle B03335-02 INT.
  • Page 19 Figure 10: Parts List - With variable speed motor ECM...
  • Page 20: Ecm

    Table 12: Parts List - With variable speed motor ECM ITEM PART # DESCRIPTION COMMENTS B03540 HEAT EXCHANGER ASSEMBLY Heat exchanger only J06L002 EXTRUDED JOINT 1/4 X 1/8 X 25' B03570 FLOOR ASSEMBLY B03561 INSIDE WIRE CHANEL B03572 LOWER DIVIDER ASSEMBLY Includes panel, 3 gaskets and baffle B03335-02 INT.