2-channel constant voltage PWM dimmer for DC LED loads
ZDILX2V2
FEATURES
2 constant voltage configurable channels (combinable
independent channels and TW channel)
1 relay to control the LEDs power supply or for independent
use
Supports KNX Data Secure
Master Light control
External 12-40 VDC power supply
Manual output operation with push button and LED status
indicator
Total data saving on KNX bus failure
Integrated KNX BCU (TP1-256)
Dimensions 137.4 x 55 x 30.5 mm
Surface-mounted inside panels, distribution boxes or false
ceiling
Conformity with the CE, UKCA, RCM directives (marks on the
right side)
1. Power Supply Relay
6. Programming button
PROGRAMMING BUTTON: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. In order to perform a KNX Secure factory reset, while the device is in safe mode, press the button for 10 seconds until the programming LED
changes its state.
TEST BUTTON: short press changes sequently each channel to 100%. A long press regulates the active channel.
PROGRAMMING LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. During the start-up
(reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash. The Test-On mode is indicated through green color.
GENERAL SPECIFICATIONS
CONCEPT
Type of device
Voltage (typical)
Voltage range
KNX supply
Maximum
consumption
Connection type
External power supply
Operation temperature
Storage temperature
Operation humidity
Storage humidity
Complementary characteristics
Protection class / Overvoltage category
Operation type
Device action type
Electrical stress period
Degree of protection
Installation
Minimum clearances
Response on KNX bus failure
Response on KNX bus restart
Operation indicator
Weight
PCB CTI index
Housing material
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model).
© Zennio Avance y Tecnología S.L.
2. KNX connector
3. External power supply
7. Test button
Voltage
29 VDC (typical)
24 VDC¹
Edition 1
1
2
3
4
4. Output channels
8. Power supply LED
DESCRIPTION
Electric operation control device
29 VDC SELV
21-31 VDC
mA
4.9
10
Typical TP1 bus connector for 0.8 mm Ø rigid cable
12-40 VDC
0 .. +55 °C
-20 .. +55 °C
5 .. 95%
5 .. 95%
Class B
II / III (4000 V)
Continuous operation
Type 1
Long
IP20, clean environment
Independent device to be surface-mounted inside electrical panels or
boxes. The installation is also possible in false ceiling.
Not required
Data saving according to parameterization
Data recovery according to parameterization
The programming LED indicates programming mode (red) and test mode
(green). The error LED notifies the existence of an error.
134 g
175 V
PC FR V0 halogen free
Further information
Lumento X2 v2
TECHNICAL DOCUMENTATION
Figure 1: Lumento X2 v2
5. Programming LED
9. Error notification LED
mW
142.1
240
www.zennio.com
5
6
7
8
9
Page 1/2

Advertisement

loading

Summary of Contents for Zennio Lumento X2 v2

  • Page 1 Integrated KNX BCU (TP1-256) • Dimensions 137.4 x 55 x 30.5 mm • Surface-mounted inside panels, distribution boxes or false Figure 1: Lumento X2 v2 ceiling • Conformity with the CE, UKCA, RCM directives (marks on the right side) 1. Power Supply Relay 2.
  • Page 2 • The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructi ons at https://www.zennio.com/en/legal/weee-regulation. • This device contains software subject to specific licences. For details, please refer to https://zennio.com/licenses. © Zennio Avance y Tecnología S.L.