MG 18KDU Instruction Manual
MG 18KDU Instruction Manual

MG 18KDU Instruction Manual

Current loop supply (10 – 50 ma / 4 – 20 ma loop)

Advertisement

Quick Links

INSTRUCTION MANUAL
CURRENT LOOP SUPPLY
(10 – 50 mA / 4 – 20 mA loop)

BEFORE USE ....

Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.

POINTS OF CAUTION

■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 105mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
MODEL

COMPONENT IDENTIFICATION

■ FRONT VIEW (with cover open)
• Without Power Switch
Span Adj.
Zero Adj.
• With Power Switch
Power Switch
Span Adj.
Zero Adj.

INSTALLATION

Use Standard Rack (model: 18KBXx).
18KDU
Body
Specifications
Front Cover
(Connection diagram
behind)
7 8
5 6
1
2
3 4
7 8
5 6
1
2
3 4
EM-0428 Rev.2 P. 1 / 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 18KDU and is the answer not in the manual?

Questions and answers

Summary of Contents for MG 18KDU

  • Page 1 10 minutes is required for satisfying complete performance described in the data Use Standard Rack (model: 18KBXx). sheet. EM-0428 Rev.2 P. 1 / 3 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 2 4 – 20mA DC or 10 – 50mA DC MONITOR V − − 1 – 5V DC Use either of module or external field terminals. EM-0428 Rev.2 P. 2 / 3 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 3 3) Check ZERO adjustment again with 0% input. 4) When ZERO value is changed, repeat the above proce- dure 1) – 3). 5) No need of adjustments for the Output 2. EM-0428 Rev.2 P. 3 / 3 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...

Table of Contents