Features
The SKJ-CRS01 Household Disinfectant Maker is a safe smart device designed to make 100% natural, non-toxic and broad-spectrum disinfectant at home. With a simple solution of salt and water, and a bit of power, the device makes medical NaClO disinfectant. NaClO disinfectant kills 99.99% of germs on hard, nonporous, nonfood contact surfaces by soak, wipe, spray. Kills E. coli, Staphylococcus aureus, Candida albicans, polio virus, etc.
The principle is the same as common industrial production of NaClO disinfectant. Electrolysis the salt water to make the NaClO disinfectant.
Product Name | Household Disinfectant Generator |
Model Name | SKJ-CRS01 |
lifespan | ≥3000h |
Operating voltage / frequency | AC100-240V~50/60Hz |
Function mode | Beauty / disinfection / washing mode |
Nominal voltage | 12V |
Weigh | 520g |
Rated power | 26W |
Sterilization rate | 99.99% |
Accessory: | host, power supply, spoon, operating instructions |
Operating
![ULTTY - SKJ-CRS01 - Operating Operating]()
Disinfectant manufacturing, Keep the lid open.
- Connect the power, the machine turn to standby, the blue LED of the cup body turn on, after the blue light is off, click the touch button to select the corresponding mode.
- Click to select and start the mode directly.
- Click once select the Beauty Mode, blue LED flicker once, machine auto start.
- Click twice in 3s select the Disinfectant Mode, blue LED flicker twice, machine auto start.
- Click thrice in 3s select Wash-water Mode, blue LED flicker thrice, machine auto start.
No operation in 3s, the machine start working and the blue LED will stay on. In working state you can disconnect the power and stop the machine.
- Working time: 3 minutes in Beauty Mode and Disinfection Mode, 10 minutes in Wash-water Mode.
- After work finished, the blue LED go off and the machine turn to standby.
Instructions
- Add water do not exceed the maximum line (330ml).
![ULTTY - SKJ-CRS01 - Instructions - Step 1 Instructions - Step 1]()
- Add salt, 1 spoon ~ 2 g
![ULTTY - SKJ-CRS01 - Instructions - Step 2 Instructions - Step 2]()
- Stir or shake 30-60s.
![ULTTY - SKJ-CRS01 - Instructions - Step 3 Instructions - Step 3]()
- Switch on and select work mode.
![ULTTY - SKJ-CRS01 - Instructions - Step 4 Instructions - Step 4]()
- The blue LED lights up and is working. (Attention: electrolysis with open lid).
![ULTTY - SKJ-CRS01 - Instructions - Step 5 Instructions - Step 5]()
- Blue LED goes out, disinfectant ready.
![ULTTY - SKJ-CRS01 - Instructions - Step 6 Instructions - Step 6]()
- Tighten the cap clockwise.
![ULTTY - SKJ-CRS01 - Instructions - Step 7 Instructions - Step 7]()
- Adjust spraying Increase air pressure.
![ULTTY - SKJ-CRS01 - Instructions - Step 8 Instructions - Step 8]()
Reference
Target | Concentration (mg/L) | Duration (min) | Instructions |
General surface | 100 250 ~ | 10 30 ~ | Wipe, soak, rinse and disinfect the surface of various clean objects. |
400 700 ~ | 10~30 | Wipe, soak, rinse, and spray disinfect the surface of various non-clean objects. |
Tableware | Sanitary Standards for Tableware Disinfection | Immersed and disinfected the cleaned tableware; washed out after disinfection. |
400 | 20 | Disinfecting the cleaned tableware used by patients with infectious disease; washed out after disinfection. |
500~800 | 30 | Disinfecting the non-cleaned tableware used by patients with infectious diseases; washed out after disinfection. |
Fabric | 250~400 | 20 | Immersed and disinfected the fabric; washed out after disinfection. |
Concentration, Time required to kill various microorganisms
Concentration (mg/l) | Duration (min) | Effect |
100 | 10 | Kill E. coli, Staphylococcus aureus≥99.99% |
200 | 10 | Kill Pseudomonas aeruginosa≥99.999% Kill Candida albicans≥99.99% |
200 | 20 | Kill Poliovirus-I vaccine strain≥99.99% |
500 | 60 | Kill Bacillus subtilis spores≥99.99% |
Working Mode
Beauty Mode
![ULTTY - SKJ-CRS01 - Beauty Mode Beauty Mode]()
Disinfectant Mode
![ULTTY - SKJ-CRS01 - Disinfectant Mode Disinfectant Mode]()
Wash-water Mode
![ULTTY - SKJ-CRS01 - Wash-water Mode Wash-water Mode]()
Function Description
Beauty Mode
Electrolysis the pure tap water, 3 minutes. (no salt!)
Function: effective removing chemicals and impurities, make extremely clean alkaline water (PH≈7.5). Its function is equivalent to basic cosmetic water.
Disinfectant Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully dissolve the salt. Run 3 minutes to make NaClO disinfectant concentration ≥ 200mg / L
Function: Spraying or soaking, for cleaning, decontaminating, sterilizing.
Suitable for toothbrushes, dentures, pet supplies, toys, air conditioners, shoe cabinets, bath towels, bedding, and various kitchen supplies.
Wash-water Mode
330ml Tap Water + 2g Salt, shake the cup 30-60s to fully dissolve the salt. Run 10 minutes to make NaClO disinfectant concentration ≥ 500mg / L
Function: Spray, soak or wipe with a towel, for sterilizing, deodorizing, bleaching and washing the items. Suitable for underwear, toilet, bathroom, trash can, hospital, sewer, and the place where mold is breeding.
Notes
- The water and disinfectant produced by this machine is for external. Do not drink and placed in a place where children can not reach;
- Operate the machine in accordance with the manual;
- Do not perform other operations during the generation process to avoid damage to the equipment;
- During the working process, it is normal for yellow willowlike precipitates to appear in the solution. This is because the water is rich in iron ions, and the above phenomenon will also occur when using table salt containing potassium ferrocyanide;
- Please use the generated disinfectant in time, otherwise the concentration of disinfectant will decrease due to the influence of light and temperature, and the residence time of disinfectant in the cup should be reduced to extend the service life of the equipment.
- Use the generated disinfectant as much as possible on the spot. Excess glass or plastic bottles should be sealed from light, dark and dry place and well-ventilated clean room, and the storage time should not be too long.
- Sodium hypochlorite disinfectant is corrosive to metals. Use with caution.
- It is forbidden to use disinfectant to sterilize and sterilize textiles woven with natural fibers other than white to prevent discoloration.
- Do not use with alcohol, vinegar, toilet spirit, or concentrated sulfuric acid at the same time.
- Disinfectant can be used to clean the humidifier, but it is not recommended to keep it in the humidifier water tank.
- When not in use for a long time, open the cup cover, store it upside down, and dry it.
WARNING
![]()
To avoid fire, electric shock, and injury, you must meet the following requirements. Otherwise, please follow the respective national and local electricity regulations
- Children, the elderly and people with disabilities or without experience should be looked after by a responsible person when using this product. Children should be supervised to ensure that they are not playing with the machine as a toy.
- Please use a separate outlet according to the current / voltage of the device. Do not use a multi-purpose socket for simultaneous use with other electrical devices.
- If the machine does not work due to a damaged power cord, switch off the power supply and ask a qualified person for repair.
- Do not pull out the plug by the cable. Pull out the plug and do not grip the cable.
- Do not stretch or energize the cable. Keep the cable away from the heat source.
- Turn off all controls before pulling the plug and pull the plug out of the socket if you are not going to use the device for a long time.
- Do not immerse the machine, power cord or plug in water or other liquids to avoid danger. The use of an extension cord is not recommended unless it has been tested by a qualified person.
- Please do not use an air cleaner or similar product directly next to the machine. Do not use detergents or lubricants for this machine and pull the power plug before cleaning, transporting and servicing the device.
- Add the specified amount of refined salt. If excessive salt is added, please stop the machine and wash the cup body with water.
- When the machine is running, pressure is automatically generated in the container, please do not give too much impact pressure. It is safer to press 1 to 10 times depending on the volume of water.
- Do not put flammable substances around the product.
- Stop using the container if it is damaged. There is a risk of explosion.
- Please use unpolluted water and refined salt. The water temperature should not exceed 50°C. This leads to a malfunction.
- Do not wash the outside of the container with water. The main unit is not waterproof.
- If the pressure is too high, do not open the cover directly, turn the product over first and press. The spray button relieves the pressure on the container before opening the lid.
- Do not drink the original solution directly.
- If the product has noises, smells and smoke, please pull out the power plug in good time and contact customer service.
![]()
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need help?
Do you have a question about the SKJ-CRS01 and is the answer not in the manual?
Questions and answers