  • Page 1 SURFACE MOUNTED BOTTLE FILLER CONVERSION Usage and Care Manual Models: AC-NNEBFPG Your Partner in Cool.
  • Page 2: Product Diagram

    PRODUCT DIAGRAM Your Partner in Cool. NOTES: *DIMENSIONS ARE REFERENCE ONLY ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKED [ ] ARE MILLIMETRES.
  • Page 3: What's Included

    WHAT’S INCLUDED PREPARATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE UNIT Remove fountain wrapper Turn OFF water supply to the unit. Bleed and remaining pressure from the lines by activating the bubbler valve. Disconnect power by UNPLUGGING the unit from the wall socket. Loosen or remove the P-trap so that the fountain nose assembly may be freely removed in the next step.
  • Page 4 PREPARATION CONT. PREPARATION CONT. Locate the solenoid valve on the Elkay unit. Disconnect both water lines from the solenoid valve. Remove fountain nose assembly. Tool Needed: T20 Torx bit Join the two water lines together using a ¼” elbow fitting (provided) (Fig. 7A). •...
  • Page 5: Installation

    INSTALLATION CONT. INSTALLATION Without taking the cooler off the wall, place the retrofit frame against the wall and set it onto The NNEBFPG comes partially assembled for shipping. Remove the kit from the packaging and the top flange of the cooler frame. separate it into the assemblies and components shown below.
  • Page 6 INSTALLATION CONT. INSTALLATION CONT. Assemble the center bracket to the holes in each of the cooler struts. Install the drip tray support bracket (keep drip tray pre-assembled) to the center bracket and frame using 4x, #8 Torx screws which are provided in the kit. Assemble the two side brackets to the cooler frame using the slotted holes on the bottom with Attach the filter guard bracket with 2x, #8 Torx screws to the frame and drip tray support two #10 screws for each bracket.
  • Page 7 INSTALLATION CONT. INSTALLATION CONT. If the outer edge of the drip tray is not properly aligned, loosen the screws on the back of the Attach one of the drain elbows to the drip drip tray support bracket and slide the bracket forward or backward as needed. Then retighten tray stem.
  • Page 8 INSTALLATION CONT. INSTALLATION CONT. Attach the ¼” union fitting to the Cooling Install the provided strain relief P-Clip to the power cord roughly 36” from the grounded plug. Tank water line out (Fig 12A). Attach it to the back side flange of the fountain frame with a #8 Torx screw. (Figure 14a). Attach one end of the provided ¼”...
  • Page 9 BOTTLE FILLER SPARE PARTS INSTALLATION CONT. Turn on water supply and check for any leaks. Ensure that nothing is obstructing the fan blade. Plug the Elkay power cord into the wall outlet. Test the contactless bottle filler by placing a water bottle into the alcove of the bottle filler. Check for leaks.
  • Page 10: Contact Name

    12 Month Comprehensive Warranty - Any defect in the appliance occuring within the first twelve months from the date of purchase will be rectified free of change by Aqua Cooler Pty Ltd or by any authorised independent Service Agent.
  • Page 11 Your Partner in Cool. Phone Numbers Address Internet Sales: 1300 278 226 U14, 2-12 Knobel Court www.aquacooler.com.au Service: 1800 278 226 Shailer Park QLD 4128 info@aquacooler.com.au...