Aqua Cooler AC-PN8EBFY Usage And Care Manual

Surface mounted bottle filler

Advertisement

Quick Links

Your Partner in Cool.
SURFACE MOUNTED
BOTTLE FILLER
Usage and Care
Manual
Models: AC-PN8EBFY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC-PN8EBFY and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aqua Cooler AC-PN8EBFY

  • Page 1 SURFACE MOUNTED BOTTLE FILLER Usage and Care Manual Models: AC-PN8EBFY Your Partner in Cool.
  • Page 2: Product Diagram

    PRODUCT DIAGRAM Your Partner in Cool. NOTES: TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED. ALLOW 4 INCHES [102MM] MIN. PER SIDE FOR VENTILATION. RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN. REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER.
  • Page 3: What's Included

    Drawing. (See page 2) The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2, as well as the instructions below. Pipe jointing and installation is a trade skill and Aqua Cooler recommended this process is performed by qualified personnel only.
  • Page 4: Chiller Installation

    BOTTLE FILLER INSTALLATION CHILLER INSTALLATION The PN8EBFY comes partially assembled for shipping. Remove the kit from the packaging and Install the wall hanger onto the wall according to the rough in drawing. The Wall hanger is separate it into the assemblies and components shown below. shipped fastened to the back of the chiller unit.
  • Page 5 INSTALLATION CONT. INSTALLATION CONT. Affix the frame to the wall with at least 4 anchors into any appropriate anchor points through the Attach the filter support bracket with 2x T15 Torx screws to the frame and drip tray support staggered slotted holes. Be careful to ensure the frame stays centered on the cooler frame. bracket.
  • Page 6 INSTALLATION CONT. INSTALLATION CONT. Assemble PN8EBFY wrapper to the installed frame. Rest the alcove on the drip tray and ensure Route the insulated cold water out line up into the bottle filler cabinet and connect it to the the wrapper walls rest OUTSIDE of the frame and side brackets. solenoid valve located above the alcove.
  • Page 7: Removing From Service

    SET-UP GUIDES INSTALLATION CONT. BOTTLE FILLER ELECTRONICS: Complete the installation by turning on the water source and checking for leaks. Factory default program settings: • Units: Gallons Ensure nothing is obstructing the fan blade. Plug the power cord back into the wall outlet and •...
  • Page 8: Maintenance

    POSSIBLE CAUSE REMEDY Controller is faulty Temperature sensor is faulty Check sensor connections. Controller display is faulty Contact Aqua Cooler service team. No water flowing out of Water source has been suspended Restore water supply the unit The system is clogged...
  • Page 9 CHILLER SPARE PARTS Your Partner in Cool. ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 041242-002 Bracket, ONN Side 041250-001 Panel, ONN Front 035080-010 Panel, Side Left STN 430 035081-010 Panel, Side Right STN 430 026794-014 Tube, Straight 031766-201 Condenser 026407-027 Elec CKT DWG W/Lead Wire P/NS 031767-004...
  • Page 10: Contact Name

    12 Month Comprehensive Warranty - Any defect in the appliance occuring within the first twelve months from the date of purchase will be rectified free of change by Aqua Cooler Pty Ltd or by any authorised independent Service Agent.
  • Page 11 Your Partner in Cool. Phone Numbers Address Internet Sales: 1300 278 226 U14, 2-12 Knobel Court www.aquacooler.com.au Service: 1800 278 226 Shailer Park QLD 4128 info@aquacooler.com.au...