  • Page 1 INSTRUCTION MANUAL ProDevice ASM240 Degausser V.ASM240.2023.2.EN Manufactured by: DISKUS Polska Sp. z o. o., ul. Kościuszki 1, 32-020 Wieliczka...
  • Page 2: Table Of Contents

    Instruction manual ProDevice ASM240 CONTENTS 1. Features 2. Packaging removal 3. Overview 4. Operation 5. Instruction video 6. Destruction of storage media 7. Safety precautions 8. Maintenance 9. Possible faults and ways to fix them www.pro-device.com...
  • Page 3 Instruction manual ProDevice ASM240 Thank you for purchasing the ProDevice ASM240 degausser. This device was designed using state-of-the-art technical know-how and manufactured using modern and reliable electrical, electronic and mechanical elements. It produces a strong magnetic field to completely delete data from magnetic storage media.
  • Page 4: Features

    Instruction manual ProDevice ASM240 1. FEATURES • ProDevice ASM240 degausser • Power cable RJ45 UTP patch cable Cat. 5 • • Media slide • Pendrive with manual instructions and software 2. PACKAGING REMOVAL The degausser is delivered to the buyer in a dedicated box or a case. The device’s weight requires at least two people to remove it from the box and subsequent transport to the place of installation.
  • Page 5: Overview

    Instruction manual ProDevice ASM240 3. OVERVIEW Front panel 1. START / STOP button 2. LCD display 3. RESET button Rear panel 4. POWER button 5. Power socket 6. Fuse www.pro-device.com...
  • Page 6 Instruction manual ProDevice ASM240 Left side view 7. Media input 8. Fan (1) 9. Side handle (1) Right side view 10. Micro PC 11. Ethernet socket 12. Fan (2) 13. Side handle (2) 14. Media output 15. IP reset button...
  • Page 7 Instruction manual ProDevice ASM240 Technical specification Power supply 115 / 230 V, 50 / 60 Hz Current steady mode 0.2 A, charging: 16 A Cycle time 30 seconds/storage medium * Magnetic induction Up to 2.2 T (22 000 Gauss) IP protection class...
  • Page 8 Instruction manual ProDevice ASM240 Descriptions of displayed messages Information on the display Meaning Welcome inscription along with the Message „ProDevice ASM240” software version Message „230V” lub „115V” Information about the set supply voltage Message „ProDevice IP” Programmed IP of the device Information while waiting for connection Message „Connecting to PC please wait...”...
  • Page 9: Operation

    Instruction manual ProDevice ASM240 4. OPERATION 1. Place the degausser on a stable surface. 2. Connect the power cord to the degausser and then to a power outlet. 3. Install the media slide in the catch located below media output.
  • Page 10: Instruction Video

    Instruction manual ProDevice ASM240 5. INSTRUCTION VIDEO Scan the QR code to watch an official video presenting correct usage of the ProDevice ASM240 degausser. The video is an inseparable part of this manual Instruction. www.pro-device.com...
  • Page 11: Destruction Of Storage Media

    Instruction manual ProDevice ASM240 6. DESTRUCTION OF STORAGE MEDIA ASM240 degausser is intended for erasing data from magnetic storage media available on the market. Putting media inside the media input enables deleting data from different media types, and media with different dimensions. There is no need to use extra connectors or adapters.
  • Page 12: Safety Precautions

    Instruction manual ProDevice ASM240 7. SAFETY PRECAUTIONS Please read the operating manual before initial start-up, operation and maintenance of the device and keep it for later use or for passing on to any subsequent users. Service may be performed by authorized personnel only.
  • Page 13: Maintenance

    Instruction manual ProDevice ASM240 • If you notice overheating of the device, turn off the demagnetizer and wait 30 minutes. Due to the weight of the device, at least two people are required to remove it from the box •...
  • Page 14: Possible Faults And Ways To Fix Them

    Instruction manual ProDevice ASM240 POSSIBLE FAULTS AND WAYS TO FIX THEM Below are the fault descriptions and the required user responses: Fault / Information shown on the display Possible cause Way to remove the fault The device does not turn on...
  • Page 15 Instruction manual ProDevice ASM240 Fault / Information shown on the display Possible cause Way to remove the fault Message „Disk NOT erased” Unsuccessful demagnetization cycle Try again. In case of failure, contact service Message „Disk NOT erased/battery” Problem with confirming the power of...
  • Page 16 INTERNATIONAL HOTLINE: +48 122 919 101 CONTACT ProDevice Spółka z ograniczoną odpowiedzialnością ul. Kościuszki 1, 32-020 Wieliczka, Poland tel. +48 122 919 101 e-mail: info@pro-device.com service: support@pro-device.com If you have an improvement idea or suggestion, write to info@pro-device.com info@pro-device.com www.pro-device.com MANUFACTURER'S ADDRESS DETAILS DISKUS Polska Spółka z ograniczoną...