Safety Warning
•
The installation should be carried out
by a qualified electrician in compliance
with the current edition of the IEE
Wiring Regulations.
•
Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
•
Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
Specification
Box Contents -
1 x Orion Street Lantern, 1 x IP Rated Connector, 1 x Low Profile NEMA3 Blanking Plug
ORN20/T3/N3/740, ORN40/T3/N3/740 & ORN60/T3/N3/740
- W: 200 x H: 568 X D: 109mm
Dimensions:
ORN80/T3/N3/740 & ORN100/T3/N3/740
- W: 240 x H: 613 D: 109mm
Body: Die-Cast Aluminium
Material:
Lens: Polycarbonate
Working
-40°C - 50°C
Temperature:
IP Rated Connector
Included:
Low Profile NEMA3 Blanking Plug
20-100
230V
WATT
Installation Instructions
Note: This is a Class I Luminaire - Earth connection is required
1.
Isolate the mains supply before commencing the installation.
2.
The Orion can be mounted in both horizontal and vertical post applications. Depending on mounting orientation follow the following steps to set the
collar to the correct angle.
3.
For horizontal installation loosen the screws on the collar, adjust the angle (if required) and then tighten to secure into position (follow the required
torque).
4.
For vertical installation fully remove the screws and the collar, rotate the mounting head and refix to the lantern head. Adjust the angle and then tighten to
secure into position (follow the required torque).
3
4
INSTALLATION INSTRUCTIONS
Orion Street Lantern
Product Codes: ORN20/T3/N3/740, ORN40/T3/N3/740, ORN60/T3/N3/740, ORN80/T3/N3/740,
ORN100/T3/N3/740,
LED
4000K
M8/22Nm
circuit breaker being turned off before
installation or any maintenance.
•
Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
•
Long-term use and voltage fluctuations
can reduce the life span of the fitting.
•
If the fitting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
IP66
IK08
M8/22Nm
•
Follow the provided installation
instructions, using the fixings supplied
or recommended.
•
Keep out of reach of children.
240mm
200mm
109mm
20W/40W/60W
80W/100W
5
YRS
Mounting Angle: - 15deg~+15 deg adjustable
Mounting Angle: - 15deg~+15 deg adjustable
109mm
Need help?
Do you have a question about the ORN20/T3/N3/740 and is the answer not in the manual?
Questions and answers