Red Arrow POL14LEDMS Installation Instructions

14w led slimline polo bulkhead with microwave sensor

Advertisement

Quick Links

14W LED Slimline
POLO Bulkhead with
Microwave Sensor
Instructions p.1
For models: POL14LEDMS
This installation must be carried out by an electrician.
Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference.

Specification

220-240V
13.5W
64pcs of 2835 SMD LED
4000K Colour temperature
1150 Lumen output
120° Beam angle
>82 Ra
3 Year guarantee

Description of Microwave Sensor

The microwave sensor option offers presence detection
to provide automatic control of lighting loads. It
is installed inside the luminaire so does not affect
external aesthetics or IP Rating. Manual adjustments
on the sensor allow it to be individually tailored to suit
your application.

Safety

This is a mains powered product. It is designed to be
installed by a qualified electrician and in accordance
with the applicable building and electrical regulations.
Before installation or maintenance the electrical
supply to the product must be isolated.
Installation Instructions
1.
Remove the diffuser & trim from the base by rotating anti-
clockwise to unlatch then pull away.
2.
Loosen the three gear tray retaining screws, rotate the gear
tray anti-clockwise to align the screw heads with the large
aperture of the keyhole slots and remove the gear tray from
the base. There is a retaining strap to assist with
installation.
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield, S6 1QS
Installation
3.
Prepare the mains supply cable and fixing points on the
chosen mounting surface ensuring it is able to retain the
weight of the luminaire.
4.
Pass the mains supply cable through the hole & grommet
provided in the base, position the base to the mounting
surface and secure using the screws provided.
5.
It is the installer's responsibility to ensure the fixing points
and cable entry point are appropriately sealed to maintain
the IP54 rating. Silicone bathroom sealant or equivalent is
recommended.
6.
Route the mains supply cable to the terminal block on the
gear tray and terminate ensuring correct polarity is
observed.
7.
Secure the supply cable using the clamp provided in the
base.
8.
Refit the the gear tray and secure by retightening the
screws.
9.
Refit the diffuser and trim by placing over the base and
rotating clockwise until it locks into position.
10.
Reconnect power supply and check for correct operation.
Note: Luminaires fitted with electronic ballasts are exempt
from insulation resistance tests as this may cause damage to
the ballast.

Positioning

The luminaire and the detector should be sited so that the
occupants of the room fall inside the detection patterns
shown in the appropriate diagram on page two.
The diagram is based on a ceiling mounting height of 2.5m.
Note that the lower that the sensor is installed, the smaller the
detection range will be.
If wall mounted, the detection zone will vary depending on
the surroundings but vertical reach will be at least 10m.
Both the areas closest to and vertical to the sensor will have
the highest sensitivity.
E: sales@redarrowtrading.com
T: 0800 195 0006
F: 0870 043 3946
www.redarrowtrading.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POL14LEDMS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Red Arrow POL14LEDMS

  • Page 1 14W LED Slimline POLO Bulkhead with Microwave Sensor Installation Instructions p.1 For models: POL14LEDMS This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference. Specification...
  • Page 2 14W LED Slimline POLO Bulkhead with Microwave Sensor Installation Instructions p.2 For models: POL14LEDMS • The distances quoted are approximate and may vary depending on surroundings. • Avoid direct sunlight entering the sensor. • Do not site within 1m of forced air heating or ventilation.
  • Page 3 14W LED Slimline POLO Bulkhead with Microwave Sensor Installation Instructions p.3 For models: POL14LEDMS The LED setting indicator will flash to indicate the setting selected as follows: No. of Flashes Setting Length 10 seconds 1 minute 2 minutes 5 minutes...
  • Page 4 14W LED Slimline POLO Bulkhead with Microwave Sensor Installation Instructions p.4 For models: POL14LEDMS • Ensure the luminaire is not connected in parallel with other luminaires containing microwave sensors. MAINTENANCE • Cleaning should be carried out at regular intervals so it doesn’t impair photometric performance or thermal safety of the luminaire.

Table of Contents