Download Print this page

Oasis AQUA POINTE MWRSBF User Manual page 2

Drinking fountain with sports bottle filler

Advertisement

OASIS
AQUA POINTE
®
INSTRUCTIONS
1. INSPECTION
Inspect the cartons and various components for evidence of rough handling and concealed damage. Damage
claims should be filed with the carrier.
2. MAINTENANCE (Fountains with Cooling Unit)
The only maintenance required is the removal of dirt and lint from the condenser. Inspection should be made at
3 mount intervals. Remove the grille and clean the condenser with a vacuum attachment.
3. OVERLOAD PROTECTION (Fountains with Cooling Unit)
The compressor motor is equipped with an automatic reset protector which will disconnect the compressor
motor from the power source in case of overload.
4. LUBRICATION (Fountains with Cooling Unit)
This unit is equipped with a sealed fan motor and hermetically sealed compressor. No additional lubrication is
required.
5. TO DISCONTINUE USE OF FOUNTAINS WITH COOLING UNITS
Drain cooler when removed from service: (1) Remove grille, (2) Close supply valve, (3) Provide container to catch
water, and remove drain plug, (4) Remove bubbler.
7. INSTALLATION, PLUMBING & ELECTRICAL CONNECTIONS
a) Note: The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX,
VT and WI. CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well. State and
local plumbing codes may prohibit the use of saddle tapping valves for water line connection in some
applications. All connections must conform to applicable plumbing codes.
b) Plumbing rough-in and wall opening should be prepared as shown on Roughing-in drawing. This drinking
water cooler is designed to be operated at a water supply line pressure of up to 100 psi (690 kPa). A pressure
regulator must be installed in front of the unit's water inlet if the water pressure (including any possible
pressure spikes) could exceed 100 psi (690 kPa).
c) Insert frame assembly into wall opening and secure to studs. NOTE: FRONT FLANGE OF FRAME(S) MUST BE
FLUSH WITH THE FINISHED WALL SURFACE.
d) Models with cooling unit, refer to page 7 diagram. FIRST, Secure cradle mounting angles to frame rear
flange using 4 screws provided. SECOND, slide cradle between angles and attach to angles with 4 screws
provided. (Cradle is used only when cooling unit is to be installed.) NOTE: BOTTOM FLANGE ON CRADLE IS
TO BE BEHIND FRAME FRONT FLANGE.
e) Slide cooling unit onto cradle.
f)
It is recommended that flexible conduit be used to supply power to cooling unit. Check electric current
available. Type and voltage must be the same as listed on unit data plate. This drinking water cooler is
intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL
requirements.
g) Install provided waste tee to bottle filler tailpiece.
h) Install the fountain mounting plate to the frame assembly using provided screws.
i)
Place upper panel(s) in place on frame top angle and fasten with 2 flat head screws, provided, at the bottom.
j)
Remove bottom plate(s) from fountain arm(s). Save the screws.
k) Snap reveal gasket(s) over back end(s) of fountain arm(s).
l)
Add compression connector(s), furnished by others, to fountain waste tube(s) and slide back approximately
3" out of way. Use a 3/8 compression fitting for water line connections, provided by others. An internal
strainer is provided for water line connection. For dielectric isolation of fountain(s) a non-metallic water line
connection can be used.
DRINKING FOUTAIN WITH SPORTS BOTTLE FILLER
®
2 of 8

Advertisement

loading

This manual is also suitable for:

Aqua pointe m8wrsbfAqua pointe m12wrsbfAqua pointe m8crsbfAqua pointe m12crsbfAqua pointe mmrslsbf