A. INSPECTION
Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage. Damage claims should be filed with the
carrier.
B.
TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE
1.
NOTE: The following states require a licensed plumber to install cooler; AG, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI.
CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well. State and local plumbing codes may prohibit the use of
saddle tapping valves for water line connection in some applications. All connections must conform to applicable plumbing codes.
2.
The P8ACSL/ADA8ACB is composed of a water cooler and a water fountain. The water cooler contains the refrigeration system and is
always mounted on the right side. This unit can be configured with the water cooler high or low. Refer to the proper roughing in drawing for
location of plumbing and electrical service.
3.
FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT.
4.
Install wall hangers as shown on the desired roughing in drawing. Wall hangers are shipped fastened to the backs of the unit. Units with
factory installed filters have additional instructions on a label inside of the access panel. Read these before installing the unit.
5.
To configure this cooler for right side high or right side low installation, refer to the details below. The bottom screws of the
appropriate side panel may be temporarily removed to install the patch plate. Assemble the drains as shown below, matching the
position of the gaskets to the contour of the cooler tops.
6.
Mount the water cooler on the right hanger.
7.
Straighten the inlet "Water In" tube in the water fountain. Mount the water fountain on left side hanger while routing the "Water In" tube
through the access hole to the water cooler. Remove the plug from the "Drain/Remote Cold Water" connection and insert the "Water In" tube.
8.
All provided waste drain parts for field installation are packed in the water fountain. Assemble the drain per the appropriate
roughing in drawing. The short leg of the crossover piece will be on the water cooler side. When the unit has an internal waste trap,
the trap should be wrapped with insulating tape to prevent sweating. The use of the 1-3/4" knockout for a waste line is not
recommended because of a potential conflict with ADA* toe space requirements. Check with your local building code inspector for
approval.
9.
Install a shut off valve in water supply line. Remove the strainer from the cooler "Water Supply" tube. Solder 3/8" inlet tube extension
(furnished) with lead free solder to "Water Supply" tube and insert the strainer in open end of extension. Connect extension to shut off valve.
To allow access to strainer for service, this connection should not be a solder or flare joint. To ease removal of the strainer, a sheet metal
screw may be lightly threaded into the open end.
10. Rotate the fan blade by hand to see that it is free of obstructions.
11. Check the available power supply against the water cooler data plate to assure correct electrical service. Plug power supply cord into wall
outlet. The rear most 1-3/8 diameter knockout in the frame bottom is for an externally located electrical supply. Make sure the knockout hole
edge is smooth and free of any burrs. Use of a Heyco busing #2184 in the knocked out hole is recommended in order to prevent damage to the
service cord and to close up excess opening around the cord. Route the cord so it does not interfere with ADA* space requirements.
12. To fill the cold water tank on the water cooler, open the water supply line shut-off and push any one of the front pushbuttons to allow water to
flow to the bubbler. On The EE model, actuate the solenoid by holding one hand approximately 3 inches from the infrared sensor. Run water
until stream is free of bubbles.
13. To adjust bubbler stream:
a)
All pushbutton models are equipped with a cartridge regulator. The P8ACSL/ADA8ACB and PF8ACSL/ADAF8ACB have a slot in the
shelf below the pushbuttons. Insert a screwdriver in this slot to adjust regulator. Turn adjustment clockwise to increase stream height.
To access PV8ACSL and PFV8ACSL adjustment, remove the bezel and button from the front of the cooler.
b)
Electric eye (EE or HF) models have a regulator built into the bubbler. If adjustment is needed, insert a 5/64 wrench approximately 1-
1/8" into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw. Turn the adjust screw clockwise to reduce the
stream height or counterclockwise to increase the height. Note, less than one turn is required to go from a closed to a wide open flow.
Do not overtighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result.
14. To adjust the beam range of the sensor (EE or HF models only):
a)
Shut off the water and power supplies.
b)
Remove the two screws from the top front.
c)
Remove the eight screws from the bottom of the nose that holds the nose to the shelf.
d)
Remove the nose to gain access to sensor adjusting screw located between the two lenses.
e)
The screw can be turned a maximum of ¾ turns. Turn screw counterclockwise to decrease range. The sensor has an adjustable range of
24" to 48". It is factory set at 27". There is a non-adjustable on-time delay of .75 seconds to prevent nuisance actuation of the solenoid
valve should someone walk by. After drinking, the water will shut off immediately after walking away. Maximum run time is 30
seconds should someone tamper with the sensor. NOTE: Walls with a reflective finish, i.e., ceramic tile, across from the sensor may
cause false actuation no matter what the sensor adjustment is for distance. Therefore, do not install the unit in such an area or dull the
surface of the wall so it will not reflect light.
C. MAINTENANCE
The only maintenance operation required is the removal of dirt and lint from the condenser of the water cooler. Inspection should be made at 3-
month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire brush when required. Observance of this
procedure will ensure adequate air circulation through the condenser so operation is efficient and economical.
®
OASIS
VERSACOOLER
INSTRUCTIONS
®
II MODELS

Advertisement

loading

Summary of Contents for Oasis VERSACOOLER II Series

  • Page 1 ® ® OASIS VERSACOOLER II MODELS PACSL, P8ACSL, P8ACSLEE, PF8ACSL, PF8ACSLEE, PV8ACSL, PVF8ACSL, PGACSL, PG8ACSL SUNROC MODELS ADA8ACB, ADA8ACBHF, ADAF8ACB, ADAF8ACBHF INSTRUCTIONS A. INSPECTION Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.
  • Page 2 INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 222 East Campus View Blvd. • Columbus, OH 43235 U.S.A. 1-800-950-3226 www.oasiscoolers.com is a trademark of Oasis International © 2009 Oasis International ® OASIS is a registered trademark of Oasis International 030099-350 Rev C...
  • Page 5 ® VERSAFILLER ® Model PWEBF (retro fit) and P*EBF Family of Drinking Fountains/VersaFiller combo Installation Instructions The Hands-Free VersaFiller is an extension of the Aqua Pointe product line ® that mounts directly above Versacooler I and II products. If the cooler outlet ®...
  • Page 6: Section 1: Getting Started

    Section 1: Getting Started What’s Included: (Top cap) VersaFiller Hands-Free Sports Bottle Filler- (with wrapper, alcove and top cap installed Drip tray onto the frame) Gasket Anti splash grate Anti Splash Quick connect grate screws (2) tee fitting (only 38” of ¼ OD plastic required on split tubing with 19”...
  • Page 7: Section 2: Rough In Drawing

    Section 2: Rough In Drawing Oasis PWEBF: Versacooler II Models PAC, P8AC with Hands-Free VersaFiller ®...
  • Page 8 Section 2: Rough In Drawing Oasis PWEBF: Versacooler II Split Level Models with Hands-Free VersaFiller ® * On split level models, the VersaFiller must be mounted on the low unit in order to meet ADA guidelines.
  • Page 9: Section 3: Installation

    Section 3: Installation Note: Proceed to Sect 3B Step 5 if the cooler is purchased “VersaFiller ready”. A: Drilling hole in the top for water line connection. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power. Turn OFF water supply to the unit.
  • Page 10 ALIGN THIS EDGE WITH LEFT EDGE OF COOLER TOP 3-1/4” from side 2-1/8” from Mark this center point on the back top. Remove the top from the cooler. Then create a 7/8” diameter hole through the top at the marked center point (step drill bit or punch die).
  • Page 11 Section 3: Installation B: Connecting the water line Note: If you are retrofitting the Versafiller to an existing cooler, follow the instructions starting on the next page. For the single “Versafiller ready” cooler, the tube to connect to the Versafiller is found inside the access panel (the compressor compartment).
  • Page 12 The tee and tube to the Versafiller are packaged with the PWEBF unit. One branch of the tee will supply the valve on the dummy unit, the other branch of the tee will connect to the Versafiller. If a filter is being installed, cut a piece of tubing about 3” long to insert flow switch right after filter and before tee.
  • Page 13 To retrofit the Versafiller to an existing unit, follow the instructions below: If the cooling tank is non-pressurized, then go to the “Pressurizing the cooling tank” addendum section. Otherwise, proceed to step 1 below. Non-pressurized units are single units made since December of 2009. Refer to the schematic below to identify the system that you have.
  • Page 14 Section 3: Installation: For the P8AC Version: Versacooler II Disconnect tubing from the elbow on the valve. Using the 38” piece of tubing provided, cut 6” and install it 32” tubing on the end of the TEE. Install the remaining tubing onto the branch of the TEE.
  • Page 15 Section 3: Installation: For the P8AM Version: Versacooler I Remove tar tape Remove tar tape from the insulation on the outlet tube. Pull back insulation and cut the copper tube with a tubing cutter. Cut where there is at least 1 inch of straight tubing on each side of the cut.
  • Page 16 Section 3: Installation: Final steps for both product families: 5. Feed black and blue tubing up through bushing in top. • For single unit, also feed white tube attached to tee through bushing. • For split level, connect tee and white tube packed with bottle filler per schematic below.
  • Page 17 Section 3: Installation C: Mounting the frame to the wall 1. Place rubber gasket on top of the cooler so it is centered left/right and against the wall.
  • Page 18 Section 3: Installation 2. Set the wall frame onto the gasket. Center it left/right and push it against the wall and mark hole locations for wall fasteners. The gasket will set the frame at the proper height. Use mounting slots that will provide the proper securing location.
  • Page 19 Section 3: Installation 5. Set the VersaFiller cabinet into place. As you do, feed the terminals on the power supply power cord and the 30”(76 cm) long green ground wire through the bushing on the cooler top. MAKE SURE the cabinet fits into the groove in the rubber gasket on both sides and front of the wrapper.
  • Page 20: Installation Complete

    Section 3: Installation 7. Install the drip tray and anti-splash grate into the alcove area and secure with the two (2) stainless steel phillips head screws. Anti-splash grate screws (provided) Anti-splash grate Drip tray 8. Connect male tab terminals from bottle filler power supply to female terminals on power cord.
  • Page 21: Section 4: Set-Up Guide For Bottle Filler Electronics

    Section 4: Set-up guide for bottle filler electronics Factory default program settings are: • Units - Gallons • Bottle Count = 0.5L (1 Bottle) • Unfiltered unit • Flow Rate = 1.2 GPM • Filter Capacity = 1250 gallons [4731 liters] for a VersaFilter •...
  • Page 22 Addendum Section: Pressurizing Cooling Tank The water should already be turned OFF and the power disconnected. Unit as it appears with top removed STEP 1 Unplug un-insulated water line from water valve inlet (quick-connect elbow located left side of water valve facing the front of the cooler).
  • Page 23 STEP 3 Plug un-insulated tubing that was removed in step 1 into quick-connect elbow leading to the cooling tank from step 2. STEP 4 Unplug tubing that is connected to the water valve outlet (quick- connect elbow located on the right side of valve facing the cooler).
  • Page 24 Step 6 Unplug quick-connect tubing from the cooling tank outlet. Do not set it down. Step 7 Using tubing removed in step 6, plug into quick-connect elbow on the right side of the valve. (be sure to route the tubing under existing tubing installed in step 4 as shown)
  • Page 25 Date: 3/2018 © 2018 LVD Acquisition, LLC Oasis, Aqua Pointe, Versacooler and VersaFiller are registered trademarks of Oasis International LVD Acquisition, LLC dba Oasis International. A WBENC – Certified Women’s 222 East Campus View Blvd. Business Enterprise Columbus, OH 43235 Haws is a registered trademark of HAWS Corporation.