This document describes the Microsemi Access Point Power Injector PWR-INJ60GO/AC-NA
(AIR-PWRINJ-60RGD1= and AIR-PWRINJ-60RGD2=, referred to as the power injector in this
document) and provides instructions for mounting them.
The following information is provided in this document:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWR-INJ60GO/AC-NA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Microsemi PWR-INJ60GO/AC-NA

  • Page 1: Table Of Contents

    Installation Instructions PWR-INJ60GO/AC-NA (AIR-PWRINJ-60RGD1= and AIR-PWRINJ-60RGD2=) This document describes the Microsemi Access Point Power Injector PWR-INJ60GO/AC-NA (AIR-PWRINJ-60RGD1= and AIR-PWRINJ-60RGD2=, referred to as the power injector in this document) and provides instructions for mounting them. The following information is provided in this document: •...
  • Page 2: Product Overview

    The power injector’s AC power receptacle connects an approved AC power cord to a wall outlet or power strip. The power injector can be mounted on most horizontal and vertical surfaces, but must be mounted in a vertical orientation to comply with safety requirements. Microsemi Power Injector Installation Instructions...
  • Page 3: Pwr-Inj60Go/Ac-Na= Technical Specifications

    VCCI Electromagnetic Emission & Immunity EN61000-4-5 Class 5 (6kV CM) UL60950-1 & UL60950-22 Safety Approvals GS Mark Meets Surge Protection as specified in GR-1089-CORE Issue 4 Surge Protection ITU-T K.20 6 kV on AC lines Microsemi Power Injector Installation Instructions...
  • Page 4: Important Safety Information

    You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Microsemi equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures: •...
  • Page 5 Safety Precautions Translated versions of the following safety warnings are provided in the Safety Warnings document that ships with the access point and is also available on Microsemi.com. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 6: Connectors On The Power Injector

    To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023 Warning Connectors on the Power Injector Figure 1 Earth Ground Connector on the Head of the Power Injector Figure 2 Power and Data Connectors on the Base of the Power Injector Microsemi Power Injector Installation Instructions...
  • Page 7: Unpacking The Power Injector

    (Figure • Ground cable (Figure If any item is missing or damaged, contact your Microsemi representative or reseller. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023 Warning Note You must use shielded outdoor rated Ethernet cables with this device.
  • Page 8: Mounting The Power Injector On A Wall

    Figure 1), and attach then other end to a permanent ground connection. The ground lug used is an M6 stud. Step 5 “Connecting Data and Power to the Injector” section on page Proceed with the Microsemi Power Injector Installation Instructions...
  • Page 9: Pole Mounting The Power Injector Using Air-Pwrinj-60-Pmk

    Mount the metal bracket of the AIR-PWRINJ-60-PMK= at the required position on the pole. Step 2 Fasten the bracket to the pole using the worm screw clamps and the M6*110 hexagon head screw, flat washers, lock washers, and hexagon nuts. See Figure Microsemi Power Injector Installation Instructions...
  • Page 10 Earth Ground connector on the head of the power injector (see Figure 1), and attach then other end to a permanent ground connection. Step 5 “Connecting Data and Power to the Injector” section on page Proceed with the Figure 5 Pole-Mounting the Power Injector Microsemi Power Injector Installation Instructions...
  • Page 11: Connecting Data And Power To The Injector

    Connect the other end of the power cord into a 100-VAC to 240-VAC power source Table 1 AC Power Cord and Wire Sizes Type AC Cord Sizes Individual AC Wire Sizes RGD2= 6.8mm +/-0.4mm 0.75mm/3C RGD1= (for reference only) 8mm +/-0.4mm 18AWG/x3C Microsemi Power Injector Installation Instructions...
  • Page 12 Connecting Data and Power to the Injector Figure 6 Assembling of Factory-Shipped Waterproof RJ45 Connectors Microsemi Power Injector Installation Instructions...
  • Page 13: Power Injector Input And Output Connections

    Ethernet signal pair (10/100/1000Base-T) and 55 VDC return Ethernet signal pair (10/100/1000Base-T) and 55 VDC (+) Ethernet signal pair (1000Base-T) and 55 VDC (+) Ethernet signal pair (1000Base-T) and 55 VDC return Shield Chassis ground Microsemi Power Injector Installation Instructions...
  • Page 14 Power Injector Input and Output Connections Microsemi Power Injector Installation Instructions...