1.16 KIT CONNECTION CABLE PATH DIAGRAM.
The power cable (l) must follow the prescribed route (Fig. 25).
If the power supply cable is damaged, it must be replaced by a special cable or assembly,
which are only available from the manufacturer or its Authorised After-Sales Technical
Assistance Centre. It is recommended to contact a qualified company (e.g. the Authorised
After-Sales Technical Assistance Centre) for replacement to avoid a hazard.
To protect from possible dispersions of DC voltage, it is necessary to provide a type A
differential safety device.
The power supply cable must be connected to a 230V ±10% / 50Hz mains supply respec-
ting L-N polarity and earth connection; this network must also have a multi-pole circuit
breaker with class III overvoltage category in compliance with installation regulations.
48
48
1
M8
M6
B12
B11
A12
25