Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
FOR SURFACE MOUNT HOUSING: CONTROL BOX #0
STEP 1. FAUCET INSTALLATION
Depending on the installation, use the 063160A thin wall kit OR 063161A thick wall kit
(both provided as standard). Connect 20" braided hose to spout inlet. Clean surface
where faucet will be mounted. Install faucet to sink/wall using nut and washer provided.
Ensure gasket is centered on faucet prior to tightening. Do not overtighten the nut or
reposition the faucet once installed, otherwise damage to the gasket may result.
Cutting or trimming of the gasket is not recommended. If the gasket is trimmed or
modified, then clear silicone sealant should be used between the faucet and sink/wall
surface to prevent water leakage.
STEP 2. BATTERY BOX INSTALLATION
Mount battery box to wall under sink using the 4 supplied screws and anchors. Use
1/4" drill for wall anchors. Be sure to install the box within the dimensions provided
so the hose and spout cable will reach connections at faucet and battery box.
Refer to illustration (Fig. 2).
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 3) and run water for
1 minute. Shut off water supply. Attach aerator or flow control with adapter for #7
smooth end spouts. NOTE: Do not connect supply to the solenoid inlet until line is
flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 4) supply line
and adaptor to the bottom fitting on box, braided hose to the top fitting on box. Turn
on water supply. DO NOT SOLDER CONNECTIONS!
STEP 5. POWER UP
Unscrew the battery box lid screws (2). Install 4 "Alkaline C" batteries in holder or snap
the battery clip directly to the optional 24 VAC converter.
BATTERY VERSION
Install four "Alkaline C" batteries provided into the battery holder.
After the batteries are installed, make the sensor connection on the driver board neatly
inside the battery box. Connect battery clip to battery pack. Two beeps indicate product
is ready to use. Use caution not to damage wires or components on electronic driver
board. See Fig. 5. Secure lid using screws. Do not use 9V battery.
HARDWIRE VERSION
alent in a convenient location or in a pipe chase. (Do NOT install the transformer
inside the control box.) With the power off, bring the 24 VAC supply wires to the box.
Connect the 24 VAC supply to the 060683A conversion kit. Connect the battery snap
of the hardwire converter to the driver board battery clip. Ensure snap does not touch
anyconductive metal surface, then make the sensor connection on the control module
neatly inside the battery box. Do not remove battery snap from hardwire converter by
using a flat screwdriver, damage may result. Turn on power supply for the transformer.
STEP 6. PREPARE SINK AREA
Before connecting the spout cable – clean off counter and remove all objects
from the sink.
STEP 7. TIE SPOUT CABLE
Attach spout cable to box connector. Use tie wraps to secure spout cable to spout hose.
Your faucet is now ready for use (Fig. 2).
STEP 8. TEST FOR OPERATION
Test for operation. If faucet leaks from spout outlet: SHUT OFF WATER SUPPLIES.
Replace solenoid (2).
If faucet exhibits very low flow: A) Remove and clean spray outlet, or B) SHUT OFF
WATER SUPPLY. Clean or replace screen assembly (2). If unit does not work properly;
see Troubleshooting Guide on page 7.

INSTALLATION AND SET UP INSTRUCTIONS

Install CSA and/or UL approved Class 2 transformer or equiv-
w w w . s p e c s e l e c t . c o m
Page 2
13" (331 mm) Max.
7" (178 mm)
Max.
NOTE: Entire connection can be placed
inside battery box if desired.
For #7 Smooth
End Spouts
only
Spout
Hose
Bypass
Adapter
Ferrule
Nut
3/8" O.D.
Copper
Inlet
Fig. 4
Fig. 3
NOTE: Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.
Trap
jacket of
cable in
1
hole for
strain
relief.
Fig. 5
Tie Wraps
Fig. 2
2
212193 Rev. C