GasDog GD-600 User Manual

Industrial fixed detector

Advertisement

Quick Links

Industrial Fixed Detector
GD-600 User Manual
Please read carefully before using
1
www.gasdog.com
+86 773-280-9002
sales@gasdog.com

Advertisement

Table of Contents
loading

Summary of Contents for GasDog GD-600

  • Page 1 Industrial Fixed Detector GD-600 User Manual Please read carefully before using www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 2: Foreword

    The company is committed to continuous improvement of product performance, and the company reserves the right to improve any content in the manual without prior notice. Please refer to the actual product for the color and style of the product and product. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 3: Table Of Contents

    2.6 Info --------------------------------------------------- 2.6.1 Monitor Info ------------------------------------------- 2.6.2 Sensor Info ------------------------------------------- 2.6.3 Firmware Upgrade ------------------------------------ 10. Common faults and solutions --------------------------- 11. Terms of Service ------------------------------------------ 12. National standards for product development, design ----------- and production www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 4: Instructions Before Use

    ● Users are not allowed to repair or replace parts without authorization. ● Man-made damage is not covered by the warranty. ● It is not allowed to change the components or structures that affect the explosion-proof performance at will, so as not to affect the explosion-proof performance. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 5: Attentions

    ● The gas detector needs to be carefully tested or calibrated after an alarm occurs. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 6: Product Description

    (3) One water and dust filter (4) One manual (5) Certificate of conformity, warranty card (6) Packing box Optional accessories: (1) Switching power supply (2) Alarm light (3) High temperature probe (4) Mounting brackets (5) Power adapter(24V DC)(6) Other www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 7: Technical Parameters

    Humidity: 0~95%RH (non-condensing) (optional external filter will be needed if the humidity is too high) Temperature: -10℃~ +55℃ (optional sampling probe will be needed if the temperature is too high) Explosion-proof grade: Ex d IIC T6 Gb www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 8: Instrument Installation

    Product structure Wire connection port Alarm light (optional) Wire connection port Infrared signal receiving port Display Shell ground terminal Status indicator Screw fixing Screw fixing hole hole Gas outlet Gas chamber Water and dust filter Gas inlet www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 9 Note: The installation location must be well grounded or insulated. Leakage of electricity may cause the detector to work abnormally. * Other installation methods such as horizontal pipe, vertical pipe can be adjusted according to site conditions www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 10 To detect harmful gases heavier than the air index, the sampling point should be installed below the operating environment. Commonly, gas weight is similar to air, their sampling point installation height should be 1.5 meters above the ground . Gas outlet Filter Sampling tube Sampling side www.gasdog.com +86 773-280-9002 sales@gasdog.com -10-...
  • Page 11 Reference distance = (500-Rc) ÷ Rm * Rc-input resistance of control system, Rm-resistivity of transmission cable. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 12 Warning: When the instrument alarms, you must leave the workplace as soon as possible. Otherwise, serious personal injury or personal injury may be caused. Please re-calibrate and check the detector afterwards to avoid the expansion of equipment errors and cause false alarms. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 13 A. RS485 digital signal output connection mode 1. (can be independently grounded) Control panel, DCS or PLC RS485A RS485B C. RS485 digital signal output connection mode 2. (can be independently grounded) PC software RS485A RS485-USB RS485B adapter www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 14: Remote Control Instruction

    8. Left key: move the cursor to the left; select the position to modify the data. 9. Right key: move the cursor to the right; choose to modify the data position. 10. Add key: increase the value. 11. Minus key: decrease the value. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 15: Function Description

    After the startup is complete, the reading and various function icons will be displayed on the screen. 1.2 Power Off In the normal measurement state or when there is power, just disconnect the power. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 16: User Interface

    8) Address number: detector address When the following screen appears, please check the device. Loss of signal: The detector is not connected or has poor contact. After the reconnection is correct, the interface still appears, please contact the manufacturer. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 17: Main Menu Interface Operation

    2. Before do this operation, it is recommended to start up and warm up for 10~20 minutes. 3. When performing this operation, please turn on the instrument and place it in pure air for 3-5 minutes, and wait for the value to stabilize before proceeding, otherwise the displayed data will be inaccurate. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 18: Span Calibration

    flow meter. During ventilation calibration, ensure that the emptying of the bypass flow meter is above 100mL/min. In the span calibration interface, press the "OK" key to enter the span calibration sub-interface. Pressure reducing Flowmeter valve flowmeter Emptying Ensure Calibration normal exhaust PTFE tube T-tube www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 19 3. Setting value: the actual concentration of the calibration gas currently input. 4. When selecting the calibration point, please follow the principle of "zero point < calibration point≤ range", otherwise the calibration will be failed. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 20: Alarm Set

    Low alarm : no low alarm, light is off; low alarm, red light is on. High alarm: no high alarm, light is off; high alarm, red light is on. Fault: no fault, no light; self-test fault, orange light www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 21: Monitor

    Detector 2, the address is set to 005, channel C1 is 005, channel C2 is 006, channel C3 is 007, and channel C4 is 008. By analogy, the set address is determined by the channel quantity. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 22: Current Setting

    +86 773-280-9002 sales@gasdog.com...
  • Page 23: Reset

    In the "Reset" interface, press the "BACK" key back to previous menu. Note: The reset operation is irreversible. After reset, the parameters set by user will be cleared and can't be restored. Please use it carefully. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 24: Language Setting

    Sensor info including gas type, measure range and ADC value 2.6.3 Firmware Upgrade For online upgrade, you need to use the PC terminal to operate. For details, please consult the sales staff or check the relevant operating instructions. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 25: Common Faults And Solutions

    In case of special circumstances, if the repair cannot be completed within 7 valid working days, our staff will call in advance to negotiate the repair date with you. The aforementioned restoration dates do not include shipping time. www.gasdog.com +86 773-280-9002 sales@gasdog.com...
  • Page 26: National Standards For Product Development, Design

    JJG 365-2008 "Regulations for the Verification of Electrochemical Oxygen Meters" JJG 693-2011 "Regulations for the Verification of Combustible Gas Detection Alarms” Other: GB 12358-2006 "General technical requirements for ambient gas detection and alarm instruments in workplaces” www.gasdog.com +86 773-280-9002 sales@gasdog.com...