Software Upgrading Instruction
7
Software Upgrading Instructions as Table 7
Location
Part No.
N102
5272532007
N102
5272532007
8 Software (FALSH) upgrading methods
8.1 Execute ALL-100 upgrading file GSEEP.EXE;
8.2 Click menu Device, select FLASH model EN25Q32B shown as Fig. 3;
Note: real FLASH model depends on the real material, models shown by Fig. 3 are just for illustration.
8.3 Click toolbar AUTO, enter into interface AUTO, make sure to tick off option Config when
upgrading Flash. Please refer to Fig. 4.
Table 7
Software Upgrading Instruction
Part model
EN25Q32B-104HIP
EN25Q32B-104HIP
Fig. 3 Device model selection interface
Fig. 4 AUTO upgrading interface
Upgrading
Software functions
before SMT
Main Software
HDCP KEY
Upgrading method
Yes
Upgrade with ALL100, etc.
Yes
Upgrade with ALL100, etc.