Download Print this page

Fritz Gegauf BERNINA 1230 Service Manual page 23

Advertisement

What is to be tested
What to adjust
Normal condition
Print P-4200
-
Initial state of service operation
(page 17)
a) Using the handwheel
- LEDs SL, SB and stop not illuminated
bring needle to its zero position (lowest pos.)
on the service panel
b) Rotate handwheel forwards and
check table to the right
LED
LED
LED
SL
SB
STOP
on
on
off
on
on
on
on
off
on
off
off
on
off
off
off
'I
a
Important:
__
If the print does not function as required
per the table, then repeat tests a) and b)
using a new print. If there are still
discrepancies then refit the old print,
replace print S-1230, and repeat tests a)
and b).
wo
N,

Advertisement

loading