Mode! 5355A
Genera! Information
Table 1-1. Model 5355A Specifications (Continued)
5356A OPTION 001 HIGH PASS FILTER
DEFINITIONS
SPECIFICATIONS
Insertion Loss:
<1 dB from 1.5—18 GHz
LSD Displayed:
Unit value of least significant digit.
insertion Loss below 100 MHz: >35 dB
Resolution:
Maximum deviation (or rms deviation)
between successive measurements under
constant environmental and constant input
conditions.
GENERAL
Accuracy:
Deviation from the true value as fixed by
universally accepted standards for frequency
and time.
IF OUT:
Down converted signal in range of
80—375 MHz available at 5355 rear panel
Minimum
For a pulsed rf input, the required minimum
IF OUT connector. 0 dBm NOMINAL level.
GATE OUT:
0 to -1 volt detected if signal used to drive
ON/OFF Ratio:
difference, in dB, between the pulse ON signal
level and pulse OFF signal level which will
enable the 5355 to distinguish a pulse input.
5345A EXTERNAL GATE CONTROL INPUT.
Maximum Video
For a pulse rf input, the maximum peak-to-
Width of GATE OUT is approximately 30 ns
less than rf burst width.
PULSE OUT:
Detected IF signal: TTL levels; TTL low
Feedthrough:
peak voltage caused by the superposition of
video components above 75 MHz, which the
5355/56 can tolerate in the burst.
indicates signal present; +1 to 0V TYPICAL
rms jitter =
.1.
,
V
into son.
\J(5345A GATE TIME) (EXT GATE WlDTH)
X = 100 Hz rms
For EXT GATE signals generated by the 5355A,
the EXT GATE WIDTH equals the input PULSE
WIDTH minus 30 ns (TYPICAL) for the
5356A/B/C input and equals input PULSE
width minus 40 ns (TYPICAL) for the
5355 0.4—1.6 GHz input.
Operating
Temperature:
0° to 55°C
Weight;
5355A: 3.75 kg (8 lb., 4 oz.) net
5356A/B/C: 0.54 kg (1 lb., 3 oz.) net
5356A/B/C
27.4 mm, 138 mm,56.6 mm (1.08',5.43 ,2.23 )
Dimensions:
Cable length: 1.68 metres (66")
1-13.
SAFETY CONSIDERATIONS
1-14.
This product is used as part of a Safety Class I instrument (provided with a protective earth
terminal). Safety information pertinent to the operation and servicing of this instrument is
included in appropriate sections of this manual.
1-15.
EQUIPMENT SUPPLIED
1-16.
The only equipment supplied with the 5355A plug-in unit is the BNC Cable (HP Part No.
05355-60101) shown in
Figure 1-1.
1-17.
ACCESSORIES
1-18.
Accessories available for use with the 5355A are as follows (connector and filter options
listed in
Table 1-2):
5356A Frequency Converter Head (1.5—18 GHz)
5356B Frequency Converter Head (1.5—26.5 GHz)
5356C Frequency Converter Head (1.5—40 GHz)
Extender Board Service Kit, HP Part No. 05355-60100 (See paragraph 1-19)
APC 7 to N(f) Adapter, HP 11524A