Remote
External
probe
Electrical
power supply
Ambient
Thermostat
Figure 5.24
The path of the external probe connection
wires must follow the path indicated in Figure
5.20.
Make the boiler cables exit using specific cable
glands O (Figure 5.21).
5.14 Electrical connection of the re-
mote (optional)
Use the terminals indicated in Figure 5.24 to
connect the remote.
To connect the remote control to the boiler, re-
fer also to the REMOTE CONTROL manual.
The electric jumper connected in the am-
bient thermostat terminal board between
terminals "1 and 3" should not be removed
Figure 5.24.
INSTALLATION
The path of the remote control cable must fol-
low the path indicated in Figure 5.20.
Make the boiler cables exit using specific cable
glands O (Figure 5.21).
5.15 Remote enabling of operation
with the external probe
Functioning with the external probe in the
boiler must be enabled if the remote control
is used.
The programming of the REMOTE (if installed)
is used to enable its operation.
• Press the button for more than 3 seconds
to enter
Figure 5.25
Press buttons
transparent programming (Figure 5.26)
Figure 5.26
• Press buttons
"PM15" program that enables the external
probe (Figure 5.27).
mode.
0
21
3
1
8
6
1 5
9
1
2
and
together to enter
or
to display the
- 43 -