  • Page 1 EKEPC3ChargingPileOCCP-1.6J protocolcontroller...
  • Page 2 ThankyouforchoosingEKEPC3ChargingPileOCCP-1.6Jprotocolcontroller. Pleasereadthismanualbeforeinstallation,operationandmaintenance. Overview ThisproductisaOCCP-1.6JprotocolvertifiedACCharigingPile ControllerwhichcanconnecttoyourAPPorbackgroundremote platformbyusingWIFI,2G/4G,Ethernetandmanyothernetwork communications.AndalsoThelocalsettingofthisproducthasa varietyofcustomizedintelligentchargingsolutionssuchas intelligentchargingandappointmentcharging. Becauseoftheadvantageswhichincludeenergysaving, environmentalprotection,easytouse,highdegreeofintelligence, thisproductcanbeapplicatedwidelyandreliableinsafety. Powersupply:AC170V-260V50Hz, powerconsumption<=3W. Operatingtemperaturerange:-25~55degrees; Relativehumidity:<95%; Height:2000m;...
  • Page 3 Instructionforusing 1.1Aboutthemanual TheInstructionscontainalltheinformationneededfordebugging andusingthecontroller. Validityrangeofthismanual Thismanualisvalidforallpartsofthechargingpilecontroller. ThisproductisbasedoninternationalstandardsIEC61851and SAEJ1772. Note:SAEJ1772isastandardforelectricvehiclechargersproposed bytheSocietyofAutomotiveEngineers. 1.2Recycleandtreatment Thematerialofthecontrollerhasenvironmentalcompatibilityand canberecycled.Inordertomeettheenvironmentalprotection requirements,pleasecontactacertifiedprofessionalcompanythat specializesinhandlingsuchwastetodealwithelectronicwaste.
  • Page 4 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile SafetyInstruction 2.1Precautionsandhazards Note:pleasefollowthesafetyinstructionsandlegalguidelines. Duetothedifferentinstallationrequirementsindifferentcountriesand regions,theinstallationpersonnelareresponsibleforensuringthatthe productinstallationcanmeetthelocallegalrequirements. Danger:voltagehazard Contactwithlivecomponentswillcauseseriousinjury.Pleasecutoffthe powersupplyofallsystemsanddevicesbeforeoperation. 2.2Fuse Warning:improperfusingmaycauseheatorfire Theinternalself-resettingfuseisonlyusedtoprotectthecontroller,and theinstallationpersonnelareresponsibleforthesafetyofthecircuit. 2.3Repair Itisnotallowedtorepair,andthedefectivedeviceshallbedisposed (abandoned)undertheconditionofmeetingtheenvironmental protectionrequirements. Warning:openingthedevicewithoutpermissioncancausedanger Openingthedevicewithoutpermissionmaycauseharmtotheuseror causesignificantdamageorpropertyloss. Note:ifthedeviceischangedinviolationofregulations,themanufacturer's warrantywillbeinvalid.Anyunauthorizedchangeswillvoidthewarranty....
  • Page 5 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile Wiringdiagramofsinglephase32A LCD--Lines SIM-Card and 4GAntenna Wi fiWith Antenna LED--Lines Modbus9600,n,8,1 Address:01H 1.5mm Rs485 Rs485 1.5mm Connect Meter Rs485 RCMU 220V 32A Power Input Rs485 Note: figure a does not need to access the system when the billing function, over-voltage protection Lock function,and over-current protection function are not enabled.
  • Page 6 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile PENDisconnectionProtectionSystem LCD--Lines SIM-Card and 4GAntenna Wi fiWith Antenna LED--Lines 1.5mm Rs485 1.5mm Connect Meter Rs485 RCMU 220V 32A Modbus9600,n,8,1 Address:01H Rs485 Note: figure a does not need to access the system when the billing function, over-voltage protection function,and over-current protection Lock function are not enabled.
  • Page 7 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile SinglePhase Wiringexample230VAC Iftheconnectionisfor cabletype,thePPline isnoneedtoconnecttohere. Out:DC 5V/100mA Modbus-RTU 9600,n,8,1 Address:01H Modbus-RTU 9600,n,8,1 Address:02H...
  • Page 8 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile ThreePhase Wiringexample400VAC Iftheconnectionisfor cabletype,thePPline isnoneedtoconnecttohere. Out:DC 5V/100mA Modbus-RTU 9600,n,8,1 Address:01H Modbus-RTU 9600,n,8,1 Address:02H...
  • Page 9 TheinstructionmanualforOCPP-1.6Jprotocol controllerofelectricvehiclechargingpile GuidenceofEKEPC3(OCCP1.6J)controller 1.Bootdistributionnetwork 1.1.1Connecttothepowersupplyandstartup,thenswipethe dediciatedcardfornetworkconfigurationtohelptheWIFIsignaltobe avaliabletolinkbydevice.Ifthecardislost,pleasecontacttothe manufacturetoreplacethecard. 1.1.2ICcardsupportedbythiscontroller:contactlessICcard,13.56MHz, M1withprotocolISO14443A standard,IC-UID 、 IC-CUID 、 IC-FUID 、 IC-UFUID,etc. 1.1.3Forcardwhichisreleasedbyourcompany,TheTagIDisalready writtenwhenitwasproduced.ThenumberofTagIDwillbemarkedon thecard(with9-digitdecimal). 1.1.4Forcardwhichissetbyyourself,theRFIDmodulewillreadthe serialnumberwhichissolidifiedincardastheTagIDnumber(with 8-digithexadecimal). 1.1.5IfyouusedtheRFIDfunctiononyourcontroller,thenyouneedto addtheTagIDatlocaldeviceorthebackgroundplatformofOCCP operationaccordingtotherequire,tohelpyouaddTagIDintoyourlist.
  • Page 10 TagID Swipethecard 1.2Useadevicethatcanreceivewirelessnetworksignals(suchasa mobilephoneorlaptop)tosearchforwirelessLAN(name:OCPP_XXXX password:88888888)andconnecttoit. WIFI successfully connected...
  • Page 11 1.3Openthebrowser,typetheIPaddress192.168.4.1toenterthelogin page. User1:ETEC-001 User2:OCPP-00001 PAS1:88888888 PAS2:88888888 1.4 Entertheparametersettinginterfaceofthelocalwebpage. Groupsof9relatedparameters...
  • Page 12 2.Thesetupinstructionoflocalwebpage TheMainmenugroupoptionsoflocalwebpage Step1:SettheinformationabouttheController Ifthetimeisdifferentbetween thefinalplatformyouconnected andyourlocalplace,pleaseenter thetimedifferencehere. Thistextisallowedtochange. Thistextisallowedtochange. Thistextisallowedtochange. Ifyourchargingpileisnotconnectedto anetworkorback-endAPP.Please selectthisoptionas:Home,otherwise itwillbepulic. Selectthecontroller'sworkmode: MasterotSlave Iftheparametersare completed,pleaseclick thisbutton.
  • Page 13 Step2:setupthenetworksystemyouaregoingtoaccess Iftheparametersarecompleted, pleaseclickthisbutton. Step3:SetuptheparametersaboutOCCPbackground'sconnection. EntertheUrlofOCCPbackgroundwhich youwanttoaccessathere.BothWSlink orWSSlinkareavaliabletouse. WhenyouchooseON:Onlyatthesituation whenthechargingpilewithoutnetwork andOCCPbackgroundisnotavaliableto authorize.IftheTagIDyouusedcannotbe foundonthelocallist,butthedevicehas yourusingrecord,itwillfindtheTagIDinthe cache.Whenbothtwomatchthenthe chargingwillbeavaliabletostart. Iftheparametersarecompleted, pleaseclickthisbutton.
  • Page 14 Step4:Settheregisteraddressforaccessingtothemeter. Illustrate:Allammeterswiththefollowingfunctionsaresupported:1)RS485 communicationinterface,communicationprotocol:Modbus-RTU.9600,n,8,1. 2)Theaddressoftheelectricitymeterissetas01H(electricitymeterformetering)and 02H(totalcircuitmeterforcurrentcollectionforDLBfunction). 3)Thedatatypeoftherequiredregisteris:4-bitfloatingpoint. IfthisisanADL400meter, enter2304,2306,2308, 2310,2312,2314,2322, 2332,2310.IftheSDM63 type0meterisentered: 0,2,4,6,8,10,52,342, 10.Forothertypesof meters,pleasereferto theinstructionmanual ofthemeteryouselected. Iftheparametersare completed,pleaseclick thisbutton. Step5:Setthebuttonforfunctionsrelatedtothechargingpile.
  • Page 15 Ifyourchargingpiledoesn't haveRFIDmoduleinstalled, pleasedisablethisfunction. IftheICcardyouuseisreleased byourcompany,selectDisable thisarea.IftheICcardyouuseis blank,selectEnablethisoption. Ifyouchargingpilehavea meterinstalled,please enablethisfunction. Ifyouchargingpilehavea meterinstalled,please enablethisfunction.
  • Page 16 Ifyouturnonthereservation function:thechargingpileis correctlyconnectedtothe carswipecardtostartthe chargingcannotstart chargingimmediately,but startcharginginthetime areayouset,andthe chargingpilewill automaticallystopcharging afterreachingtheendtime youset. IfyouareconnectinganLCD monitorthatis1602J(0.9 inches),selectthisoptionto ONstatus,otherwiseselect OFFstatus. Ifthedelaystartfunctionis on,itwillnotstarttocharge atsoonwhenthecharging pileauthorized.Butstartto chargeafterrandomdelay (in600s). Iftheparametersare completed,pleaseclickthis button.
  • Page 17 Step6:Settherelevantconfigurationparametersofthechargingpile Whenthedisplaytemperature ofthechargingpileandthe actualtemperaturevalueare different,thedisplayedvalue canbecorrected.e.g.when themeasuredtemperatureis 25.5degrees,thedisplayed temperatureis30.8degrees, enter-53here.
  • Page 18 Iftheparametersare completed,pleaseclickthis button. Step7:Setupthepre-authorizationaspect...
  • Page 19 Ifthisoptionenabled,it willsearchthealllistsof thelocaldevicelistto checkwhetherthesame TagIDnumberisornot. Ifthisoptiionenabled,The TagIDnumberwhichpre- authorizedwillbereleased bytheOCPPbackground. Ifyouclickhere,theTagID whichwillbereadwithin60s byswipingRFIDmodulecan beaddedtothelocallist. EntertheTagIDyouwantto addherethenclickthe buttonontheleftifit’ s correct,itwillbeenteredto yourlocallist. Ifyouclickthebuttonhere, yourpreviouscharging TagIDwillbedeleted. Ifyouhaveenabledthe optiontoallowcharging offline,pleaseturnthis parameterON. WhenyouselectitasON,it willallowtochargeifthe TagIDyouusedisfoundin locallist.
  • Page 20 WhentheONisselected,itstill allowtostarttochargeifthe networkdisconnect.Theall chargingrecordswillbesavedin localdevice(maximumto 10,000records)untilreconnect tothenetworkandbackground. Thelocaldevicewilluploadthe allchargingrecordswhich uploadofflinethenclearthem IfyouforgettotakeaICcardbut youremmenberyourICcard number,justentertheTagID numberhereandclickthebutton ontheleft.Thedevicewill considerthatyouhaveswiped thecard,andaccessto pre-authorizationprocess. Iftheparametersarecompleted, Step8:Other pleaseclickthisbutton.
  • Page 21 Ifnecessary,pleaseupdate thefirmware,enterthe URLhere,thenclickthe buttonontheleft,the devicewilldownloadthe firmwareautomatically. Pleasebeaware,ifthe deviceisoncharging,the uploadwillstart automaticallyafterthe chargingends.Itwill restartthedevicewhenthe uploadsucceeds. E.g:http://tb1.tpddns.cn: 6002/binFile/OCPP_en.bin Ifyouforgetit,please contacttothemanufacturer. Iftheparametersare completed,pleaseclickthis button. Step9:Completetheconfigurationthenclickthisbutton,thedevice willsavethealldatasandrestartitself.
  • Page 22 Step10: C ompletetheconfiguration,saveyourrecipefileforthe nexttouse. ExportthefileonyourPC’ s desktop 3、Importyourrecipefileandhaveaquickconfigurationofthe parameters. Selecttheconfigurationfileyousaved (ocpp_paras.json)andopenit. Importtheconfigurationfileonyourdesktop. Clickthisbuttontoconfirmyouraction.
  • Page 23 3.TheEKEPC3controllerindicatorandLCDdisplayguide State Blue Green Yellow Starting Slowflash Stratingup... LocalWebpage Fastflash settings Firmware Firmwareupgrade DrawMarquee update...XXX% Novehicleconnected Bright AvailableXXkW Vehicleconnected VehiclenotConnected Breathefast OCPPbackground communicationis Fastflash PleaseAuthorize... notsmooth Thepermissionhas Chargingfor: beendeniedbythe Slowflash hh:mm “  xxxkWh” backend Noorders,standby Bright AvailableXXkW OCPPstateA Swipeorstartremotely...
  • Page 24 CPshort-circuit CheckCPline abnormality Thediodeis CheckSocket short-circuited Bright ThePPcableis CheckPPline notconnected Lockfailstoturn Lockerror/Unlockerror onoroff DLBprotection CheckDLB RCMUprotection CheckRCMU Over-under Checkvoltage voltageprotection Overcurrent Checkcurrent protection Thechargingpile Temperature Bright temperatureistoo toohigh fast highabnormal Withoutnetwork IconorE/W/G communication WithoutOCPP Iconor0 background...
  • Page 25 4、Dimensionaldrawings(mm) Firmware APPlink1 Firmware APPlink2 download download link1 link2...