INSTRUCTION MANUAL
Electric Radiator
This manual is for the following models:
HHOA04-15
When the heater is turned on for the first time or when it has not been
used for some time, it may release a slight, harmless odour. This odour is
a normal occurrence caused by the initial heating of the internal heating
elements and will disappear with use
www.firedupcorporation.com/manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HHOA04-15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fired Up Corporation HHOA04-15

  • Page 1 Electric Radiator This manual is for the following models: HHOA04-15 When the heater is turned on for the first time or when it has not been used for some time, it may release a slight, harmless odour. This odour is...
  • Page 2: Table Of Contents

    Read ALL the instructions before use. These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause injury and/or property damage. CONTENTS Safety Instructions 03-04 Installation 05-06 Display &...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS • Read ALL the instructions before using this product. • Check that the heater and all supplied accessories are present and intact. • Always check your mains supply is the same as that indicated on the product before connecting.
  • Page 4: Installation

    has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
  • Page 5: Display & Control Panel

    Diagram A. Drill 6 x 10mm holes in the wall according to 565mm 10mm Diagram A. 30mm Insert the Wall Plugs into the holes. Screw the top hook, facing upwards, on 455mm the wall using the screws provided. Hang the radiator on the top hooks. Fit the bottom hooks between 2 fins at the bottom of the raiator, ensure the hooks are facing downwards.
  • Page 6: Icons

    ICONS Comfort Anti-Frost 3 x Weekly Heating Child Lock Mode Mode Mode Timer Programs Icon OPERATION Press the Standby key to turn the heater on or off. Setting the Day and Time Follow the steps below to set the day and time. The day and time must be set for the Timer Programs to work correctly.
  • Page 7 Anti-Frost Mode Comfort Mode ECO Mode 21 24h = The heater will work in Comfort Mode for the chosen hour. = The heater will work in ECO Mode for the chosen hour. = The heater will work in Anti-Frost Mode for the chosen hour.
  • Page 8: Maintenance

    Child Lock During any programming (in P1, P2 or P3), if there is no action for 1 minute, the screen will dim and & the Child Lock will be activated. To unlock, press and hold until the lock icon disappears. Open Window Detection Press to turn Open Window Detection on/off.
  • Page 9: Technical Parameters

    TECHNICAL PARAMETERS Information requirements for electric local space heaters Value Item Symbol Unit Item Unit 1.5kW Heat output Type of heat input, for electric storage local space heaters only (select one) manual heat charge control, with integrated [yes/no] Nominal heat out- thermostat Minimum heat manual heat charge control with room and/or...
  • Page 12: Conformity

    This product guarantee does not affect your statutory rights. CUSTOMER HELPLINE customer.support@firedupcorporation.com +44 (0) 3300 882 069 Fired Up Corporation Ltd Fired Up Buildings HD1 3LF, UK www.firedupcorporation.com Fired Up Corporation (Ireland) Ltd...