12
The data contained in the following 4 pages is for information only. Service Agents must not carry
out any repair or adjustment
to the Drive
mechanism
and
its associated
PCB
30001
during
warranty. Fauity mechanism
must be returned to AMSTRAD
for exchange.
Alignment Checks
1. Redial adjustment by use of Track 19 (Fig. 1).
List of Test Points
Test point
Name of signal
Read signal of filter outlet
Read signal of filter outlet
Signal ground
TROO sensor output
Index signal
Signal ground
BLOCK 2
BLOCK 3
BLOCK 49
500ps
200ms (TOTAL 49 BLOCKS)
INDEX
INDEX
Fig.1 Waveform of 119 (Servo pattern)
300ps