Step 12: "Start/Pause" button is pressed. Motor continues to rotate in clockwise
direction. "Clean Filter Led" starts to blink for humidity sensor short circuit control.
Open the door of tumble dryer and make the sensor short circuit by touching the
sensor plate. If short circuit control of humidity sensor is OK, "Clean Filter Led" stops
to blink, "Sound Warning Led" starts to blinks, "Sco" appears on display and it is
allowed to pass to the next step.
Important Note: At the step 10, the sensor plate needs to be short circuit in 10
seconds, otherwise short circuit error occurs. If error occurs "ScE" appears on
display. In this situation below steps must be followed:
1. Dryer must be switched off and service test have to be restarted.
2. If the same error is seen in second trial, a problem may be in humidity
3. A problem may be in humidity sensor.
4. If there is not a problem in above parts, a problem may be in main
Step 13: "Start/Pause" button is pressed. All components stop. "StP" appears on
display. After 3 seconds, "Sound Warning Led" starts to blink and it is allowed to pass
to the next step.
Step 14: "Start/Pause" button is pressed. "Drr" appears on display. Motor starts to
rotate in clockwise direction. If humidity sensor is open circuit, "Sound Warning Led"
starts to blink and it is allowed to pass to the next step. If the sensor is not open
circuit, "Clean Filter Led" starts to blink and it cannot be passed to the next step till
the sensor is open circuit.
Sensitivity: Public
Good+
sensor cables and sockets. Please check humidity sensor cables and
sockets.
board.
CONFIDENTIAL