Step 8: "Start/Pause" button is pressed. The door and compressor NTC are checked
in this step. If there is no short or open circuit sensation error, door NTC value and
compressor NTC value are sequentially shown on display and it is allowed to pass to
next step.
Door NTC Open Circuit
Door NTC Short Circuit
Compressor NTC Open Circuit
Compressor NTC Short Circuit
If NTC and voltage error occurs, it is not allowed to pass to the next step.
Step 9: "Start/Pause" button is pressed. "F On" appears on display. The compressor
cooling fan starts to work. "Sound Warning Led" starts to blink and it is allowed to
pass to the next step.
Step 10: "Start/Pause" button is pressed. "Pon" appears on display. The pump
activates. If the socket of the overflow micro switch is not connected, "Tank Full Led"
blinks. If it is connected, "Sound Warning Led" blinks and it is allowed to pass to the
next step.
Important Note: If "Tank Full Led" blinks, the overflow micro switch and cables have
to be checked.
Step 11: "Start/Pause" button is pressed. "Drr" appears on display. Motor rotates in
clockwise direction. After 3 seconds, "Sound Warning Led" starts to blink and it is
allowed to pass to the next step.
Sensitivity: Public
CONFIDENTIAL
: "d:OC" is shown on display
: "d:SC" is shown on display
: "h:OC" is shown on display
: "h:SC" is shown on display