Technics SX-P30 Service Manual page 8

Hide thumbs Also See for SX-P30:
Table of Contents

Advertisement

Key (s)
Disassembly
Assembly
1. Remove the keyboard unit (see step [3)).
1. Insert the front part of the key into the chassis.
2. Release the key claw.
2. Insert the plate spring into the hammer notch as
©
Press the front of the key downward slightly.
shown in Fig. 5.
@® Press the rear of the key forward gently.
3. While slowly lowering the key into the chassis, insert
3. To remove the key, lift it as shown in Fig. 4.
the plate spring into the notch at the rear of the key.
NOTE:
. Carefully insert the key into the opening in the chas-
*
The key claw is easily broken. Do not apply undue
sis and slide the key towards the rear to lock it in
force. Should a key claw break, it can still be used;
however, a replacement is recommended.
If a black key is to be replaced, it is necessary to re-
move both adjacent white keys. -
Removing the JACK printed circuit board
+
Remove the keyboard unit (see step [3)).
P.C.B.
1. Remove the JACK P.C.B. mounting screws (@ 2
pes.).
2. Pull out the connectors on the JACK P.C.B.
The following changes in performance may occur in the Technics Digital Piano but do not indicate trouble.
Phenomenon.
Remedy
No sound is produced when the keyboard is} «Connect the piano to the stereo set or headphones.
played.
* No sound.is produced if the VOLUME is set to MIN.
Use the sliding control to set the volume to an appropriate level.
«If thé MIDI LOCAL CONTROL is set to off, set it to on.
,
|
Data
cannot
be
exchanged
through
MIDI|-+
Match the channels on the transmitting side and the receiving side.
terminals.
* The MIDI data isn't transmitted during the demonstration performance.