smartPKM
2-channel press force measuring device
figure 1.0
TRsystems GmbH
D-75179 Pforzheim
Freiburger Straße 3
Phone: (+49) (0)7231/31520
Fax: (+49) (0)7231/315299
info@unidor.de
www.unidor.de
|
www.trsystems.de
© by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0
Page 1 of 19

Advertisement

Table of Contents
loading

Summary of Contents for unidor TRsystems smartPKM

  • Page 1 2-channel press force measuring device figure 1.0 TRsystems GmbH D-75179 Pforzheim Freiburger Straße 3 Phone: (+49) (0)7231/31520 Fax: (+49) (0)7231/315299 info@unidor.de www.unidor.de www.trsystems.de © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0...
  • Page 2 © by unidor TRsystems GmbH D-75179 Pforzheim Freiburger Straße 3 Phone: (+49) (0)7231/31520 Fax: (+49) (0)7231/315299 info@unidor.de www.unidor.de www.trsystems.de Copyright protection This manual, including the images contained therein, are protected under copyright law. Third-party applications of this manual which violate copyright provisions are prohibited.
  • Page 3: Table Of Contents

    user manual Table of contents Table of contents ..........................3 1 Change index ............................ 4 2 General ............................. 5 2.1 Scope of application ........................ 5 3 Additional safety notes ........................6 3.1 Definition of icons and notes ....................6 3.2 Supplement notes to the intended use ................... 6 3.3 Organizational measures ......................
  • Page 4: Change Index

    user manual 1 Change index Change Date Index First edition 07. aug. 23 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 4 of 19...
  • Page 5: General

    2.1 Scope of application This user manual solely applies to the following product: smartPKM Order number: 1921 1000 0000 The products are marked by attached nameplates and form part of a system.
  • Page 6: Additional Safety Notes

    user manual 3 Additional safety notes 3.1 Definition of icons and notes means that minor physical injury or property damage may occur if appropriate precautions are not taken. refers to important information and/or characteristics of and application advice for the product used. 3.2 Supplement notes to the intended use The system is designed to be used in Ethernet networks with a maximum speed of 100 Mbs for full- duplex operation specified in IEC 61158 as CPF2/2 (Communication Profile)
  • Page 7: Technical Data

    2.15 kg 5 functionality the smartPKM is a digital tonnage monitoring device with 2 channels and min/max monitoring. The device has a touch operation screen with graphical event display (channel and total force display) as well as the display of the current machine angle (virtual encoder) and display of the current stroke rate.
  • Page 8: Signals And Connection Diagram

    6 Signals and connection diagram figure 2.0 Inputs of the smartPKM/PSAeC4 power supply and EtherCat connection via M8 sockets Outputs of the smartPKM/PSAeC4 power supply via M8 sockets; EtherCat connection cable RJ45/M8; machine signals via M8 sockets of the PSAeC4 ©...
  • Page 9: Device View Connections

    user manual 7 device view connections figure 3.0 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 9 of 19...
  • Page 10: Connection Piezo Sensors

    user manual 8 connection piezo sensors the supplied piezo sensors are mounted (as shown below) in the tension or compression area of the press. To protect the encoders, please also mount the sensor protective covers before mounting and calibration. The connecting cables to the unit must not be disconnected and extended with plugs or clamps.
  • Page 11: Installation And Setup

    user manual figure 6.0 9 installation and setup wiring of the system connection of power supply; EtherCat connection and machine signals (fig. 2.0) connection of the sensors mounting the force transducers on the machine stand and connecting them to the measuring amplifier (fig.
  • Page 12 user manual figure 7.0 force angle (fig. 8.0) select "Parameters" to display the partial forces and the total force as a curve: figure 8.0 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 12 of 19...
  • Page 13 user manual force angle parameters display and settings bypass and error memory (fig. 9.0) select "Inputs": figure 9.0 parameters inputs (fig. 10.0) select "Channels": figure10.0 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 13 of 19...
  • Page 14 user manual inputs channels (fig. 11.0) select "Calibrate": figure 11.0 channels calibrate (fig. 12.0) select "adjust PSA4 booster": figure 12.0 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 14 of 19...
  • Page 15 user manual calibrate adjust PSA booster (fig. 13.0) select "save calibre. value": figure 13.0 back to channels calibrate (figure 12.0) and set the maximum channel tonnage of the machine in the table at 7.0V. Caution, incorrect specification of the maximum channel tonnage can lead to overloads and damage to the machine.
  • Page 16 user manual set tolerances (log in as a setter in the user administration, password: "111110") force angle min/max monitoring set progr. min/max value per channel (picture 14.0): figure 14.0 © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 16 of 19...
  • Page 17: Dimensions

    user manual 10 dimensions © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 17 of 19...
  • Page 18: Dimensions

    user manual 10 dimensions © by TRsystems GmbH • 75179 Pforzheim • www.unidor.de • Tel.: (+49) (0)7231/3152 0 Page 18 of 19...
  • Page 19: Ec Declaration Of Conformity

    Manufacturer: TRsystems GmbH, System department Unidor Factory: Unidor, Freiburger Straße 3, D-75179 Pforzheim hereby confirm for the Product: smartPKM Device type: Press Force Measuring Device Model name: smartPKM compliance with the EC Directive 89/392/EEC and the following standards: EN 60204.1, Electrical Equipment for Industrial Machines...