user manual Table of contents Table of contents ..........................3 1 Change index ............................ 4 2 General ............................. 5 2.1 Scope of application ........................ 5 3 Additional safety notes ........................6 3.1 Definition of icons and notes ....................6 3.2 Supplement notes to the intended use ................... 6 3.3 Organizational measures ......................
2.1 Scope of application This user manual solely applies to the following product: smartPKM Order number: 1921 1000 0000 The products are marked by attached nameplates and form part of a system.
user manual 3 Additional safety notes 3.1 Definition of icons and notes means that minor physical injury or property damage may occur if appropriate precautions are not taken. refers to important information and/or characteristics of and application advice for the product used. 3.2 Supplement notes to the intended use The system is designed to be used in Ethernet networks with a maximum speed of 100 Mbs for full- duplex operation specified in IEC 61158 as CPF2/2 (Communication Profile)
2.15 kg 5 functionality the smartPKM is a digital tonnage monitoring device with 2 channels and min/max monitoring. The device has a touch operation screen with graphical event display (channel and total force display) as well as the display of the current machine angle (virtual encoder) and display of the current stroke rate.
user manual 8 connection piezo sensors the supplied piezo sensors are mounted (as shown below) in the tension or compression area of the press. To protect the encoders, please also mount the sensor protective covers before mounting and calibration. The connecting cables to the unit must not be disconnected and extended with plugs or clamps.
user manual figure 6.0 9 installation and setup wiring of the system connection of power supply; EtherCat connection and machine signals (fig. 2.0) connection of the sensors mounting the force transducers on the machine stand and connecting them to the measuring amplifier (fig.
Page 15
user manual calibrate adjust PSA booster (fig. 13.0) select "save calibre. value": figure 13.0 back to channels calibrate (figure 12.0) and set the maximum channel tonnage of the machine in the table at 7.0V. Caution, incorrect specification of the maximum channel tonnage can lead to overloads and damage to the machine.
Manufacturer: TRsystems GmbH, System department Unidor Factory: Unidor, Freiburger Straße 3, D-75179 Pforzheim hereby confirm for the Product: smartPKM Device type: Press Force Measuring Device Model name: smartPKM compliance with the EC Directive 89/392/EEC and the following standards: EN 60204.1, Electrical Equipment for Industrial Machines...