Pinch Roller Pressure Measurement; Winding Torque Measurement In Each Mode - Akai GX-A5 Service Manual

Stereo cassette deck
Table of Contents

Advertisement

7-1, PINCH ROLLER PRESSURE MEASUREMENT
250
to 350g-cm
SPRING GAUGE.
CAPSTAN
PINCH ROLLER
SPRING
PINCH
ROLLER
PINCH
ROLLER
LEVEL
Fig. 7-1
Put in PLAY mode.
Push pinch roller arm down
with the spring gauge, push the pinch Roller 1 to 2
mm
from the Capstan and release slowly. Read the
spring gauge at the moment the pinch roller touches
the capstan and begins to rotate. Specified contact
pressure measurement of 250 to 350 grm. If there is
no measurement
obtained, Adjust or Replace the
pinch Roller spring.
7-2. WINDING TORQUE MEASUREMENT IN EACH MODE
CASSETTE TORQUE METER
Insert a cassette torque meter
(AJ-751179)
and
measure in each mode.
For Fast Forward and Re-
wind, measure at the end of the tape when the tape
has stopped running.
PLAY mode
Take up Torque:
25 to 60 grm-cm
Back tension Torque:
2 to
5 grm-cm
FAST FORWARD, REWIND mode
Take up Torque:
70 to 120 grm-cm
rm