3)After a measurement
Once the reading has been completed, remove the thermometer away from the
forehead/ear and observe the temperature.
After each measurement, you can enter the recall mode and query earlier temperature
readings.
Do not hold the thermometer for a long time, because it is sensitive to the ambient
temperature.
After each measurement, clean the temperature probe with a soft cloth, and put the
thermometer in a dry and well-ventilated place.
You should wait at least 10 seconds between each measurement.
It is dangerous to make a self-diagnosis or self-treatment based on the obtained
measurement results. For such purposes, please consult a doctor.
4)Read your temperature
To indicates a temperature reading in forehead or ear mode.
1. If 32°C≤T≤37.3°C(89.6°F≤T≤99.2°F), the white light will be on, with one long beep.
2. If 37.4°C≤T≤37.9°C(99.3°F≤T≤100.3°F), the orange light will be on, with 3 short beeps, and the
value in LCD flickers, which is a warning that you may have a slight fever.
3. If 38°C≤T≤42.9°C(100.4°F≤T≤109.2°F), the red light will be on, with 5 short beeps, and the
value in LCD flickers, which is a warning that you may have a high fever.
5)Switching between mute and un-mute
Use the toggle switch behind the machine to change the mute/unmute mode.
* Un-mute is only beep sound, not broadcast temperature value.
6)Checking 30 sets of memory data
When the thermometer is turned on or turmed off, by short pressing the "M" button by the
side to go to the memory mode, press "M" button again to check the 30 sets of memories
one by one. If no value, it will display "---".
*The memory data will be lost when removing the batteries.
7)ºF/ºC conversion
Open the battery cover, use the toggle switch to change the ºF/ºC.
Note: All the future temperature you are taking will be automatically
added the value you are adjusted.
8)To turn off
The unit will shut down automatically after 30 seconds of no use.
Or you can keep pressing the Measure button for 5 seconds.
unmute mode
mute mode
3
EN
Toggle switch

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC-IR205 and is the answer not in the manual?

Questions and answers

Tanya Jenkins
February 11, 2025

Temperature is showing as 32’ which is clearly wrong and ear temp is always red and not measuring at all.

1 comments:
Mr. Anderson
February 12, 2025

The Femometer FC-IR205 may show a temperature of 32°C and not measure ear temperature correctly due to several possible reasons:

1. Incorrect Positioning: The thermometer must be properly positioned in the ear canal to get an accurate reading. Ensure the ear is pulled correctly (straight back for infants under 1 year, up and back for older children and adults) to align the ear canal.

2. Obstruction in the Ear: Earwax or other blockages can interfere with infrared readings. Ensure the ear is clean before taking a measurement.

3. Environmental Factors: The thermometer should be kept in the same room for at least 30 minutes before measuring to acclimate to the environment.

4. Improper Use: The probe cover must be removed for ear mode, and the measurement should be taken correctly by pressing the button for one second.

5. Device Malfunction: If the thermometer consistently shows low readings, it may need calibration or battery replacement.

By addressing these factors, the thermometer should provide more accurate ear temperature readings.

This answer is automatically generated

Andrew
April 12, 2025

Hi, the thermometer seems really difficult to use and know that this should be simple so apologies. Once inserted in the ear canal and the temp button is pressed, then the audible bleep is heard once removed the numbers on the screen read 511 for a few seconds then disappear, you have then got to go to memory to get your reading, this can’t be correct is it? Thanks in advance