TROUBLESHOOTING GUIDE

DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.
PROBLEM
Unit does not operate.
No interior light
Light won't go out when door is
closed.
Unit not cold enough.
Unit is too cold.
The unit frosts up.
Freezing product.
POSSIBLE CAUSE
No electrical supply.
Loose or burned out bulb
Light on/off switch is turned to ON.
Light staying on.
Door gasket not sealing properly.
Dirty condenser coils
Air flow to front grille blocked.
High ambient air temperature or
exposure to direct sunlight.
Temperature not cold enough.
Control set too cold
High ambient temperatures or
humidity
Door gasket not sealing. Door left
open.
Product touching evaporator in back
of unit.
1075BEV
REMEDY
Plug unit in or check circuit breaker.
Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).
Turn switch to OFF (see OPERATION).
Adjust door (see MAINTENANCE, DOOR ALIGNMENT).
Adjust door (see MAINTENANCE, DOOR ALIGNMENT).
Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Air flow must not be obstructed to front grille. (See
OPERATION).
Reposition unit.
Set control to a cooler setting (see OPERATION). Allow
24 hours for temperature to stabilize.
Set control to a warmer setting (See OPERATION). Allow
24 hours for temperature to stabilize.
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Adjust door (See MAINTENANCE; DOOR ALIGNMENT).
Move product away from evaporator; make sure it is
not touching evaporator.
13