The TI035 programmable wall switch has been designed to control lightings and motors:
Load type | Maximum load | Examples |
Resistive load | 2400 W (20 A @ 120 V) |
|
Inductive load | 2400 W (20 A @ 120 V) |
|
Motor | 1 hp |
|
NOTE: This switch cannot be used if there are not at least 2 white wires joined by a connector inside the electrical box.
If the display is blank:
However, during that time, the switch is fully functional. Wait 2 minutes for the switch's built-in battery to be sufficiently charged and the screen will return to its normal contrast.
The programmable switch has 2 operating modes: manual (MAN) and automatic (AUTO). To change mode, press the switch door for 3 seconds.
The programmable switch operates as a regular switch. Briefly press the switch door to turn the lights On or Off. The mode (MAN) and state (ON or OFF) are displayed.
The programmable switch follows the programmed schedule. The mode (AUTO), state (ON or OFF) and current program number are displayed. To temporarily override (bypass) the programmed schedule, briefly press the switch door. The new state (ON or OFF) will flash to show that this state is temporary. The override remains in effect until you press the switch door again or until the beginning of the next program.
NOTE: The switch displays the time in 24-hour format by default or following a reset.
To set the switch to daylight saving time (Ad) or standard time (nor):
NOTE: By default, once you have programmed the sunset/sunrise parameters, the timer will follow the sunrise/sunset program when placed in Automatic mode. To set your own schedule, see section 8.
Fill out the following table:
Latitude | Longitude | Day # | nor/Ad | Lc |
January: 0 | March: 59 | May: 120 | July: 181 | September: 243 | November: 304 |
February: 31 | April: 90 | June: 151 | August: 212 | October: 273 | December: 334 |
nor | Standard time / Normal time / Winter time |
Ad | Daylight savings time / Advanced time / Summer time |
Once you have defined the sunset/sunrise parameters, proceed as follows:
Parameter | Defaulf setting | Possible settings | Buttons used |
Latitude (LAT) | 00 | -65 to 65 | HOUR & MIN |
Longitude (LONG) | 000 | -180 to 180 | HOUR & MIN |
Day number (DAY #) | 000 | 1 to 365 | HOUR & MIN |
Daylight savings time | nor | nor / Ad | MIN |
Local correction factor (Lc) | 0 | -1, 0, 1 | MIN |
The switch can hold up to 2 programs which are repeated every day. When you place the timer in Automatic mode, it will activate the load at the start of each program and deactivate it at the end of the program. You need to set the following parameters:
P1 ON: Start time of program 1
P2 ON: Start time of program 2
P1 OFF: End time of program 1
P2 OFF: End time of program 2
NOTE: P1 OFF and P2 OFF have priority over P1 ON and P2 ON respectively. For example, if sunrise is at 4:58 and P2 ON is set to 5:00, the lights will not turn on. You can replace the sunrise and sunset times by fixed times. Select program P1 ON or P2 OFF and enter the desired time using the HOUR and MIN buttons.
Supply: 120 VAC, 50 / 60 Hz
Maximum load: 2400 watts resistive or inductive, 1 HP motor
Operating temperature range: 5°F to 122°F (-15°C to 50°C)
Storage temperature range: -4°F to 122°F (-20°C to 50°C)
Power outage: The programs are protected by a rechargeable battery. The screen is blank during the power outage.
Solar table precision: +/- 11 min. (max error around poles)
Blank display |
|
Faded or irregular display | Ambient temperature below freezing point |
Cannot switch between 24-hour format and 12-hour format | First, press one of the control buttons so that MAN or AUTO appears on display. |
Programs do not run as expected |
|
The switch resets itself without apparent reason when used to control an inductive load such as a relay or a contactor. | The reset is caused by the load. Install a snubber (AC130-03) at each relay/contactor. |
After I have bypassed the program to turn the light Off, it turns back On at midnight. | Any temporary override (bypass) is cancelled at midnight. If you have programmed the switch to turn the light off after midnight and then you manually turn the light off before midnight, this is an override. The override will be cancelled at midnight and the light will turn back on. To ensure that the light remains Off when you bypass programming, set P1 OFF to midnight or earlier. |
If you have any questions about your light switch, go to http://www.aubetech.com, send an email to aube.service@honeywell.com or call Aube/Honeywell Customer Care toll-free at 1-800-831-2823.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Aube Technologies TI035 - Programmable Wall Switch Manual
Advertisement
Need help?
Do you have a question about the TI035 and is the answer not in the manual?
Questions and answers