ccei RNS-1 Operating Instructions Manual

Level regulation module

Advertisement

Quick Links

Table des matières
1. Technical specifications ......................................................................................................... 2
2. Pack contents ......................................................................................................................... 3
3. Installation ............................................................................................................................. 3
3.1. Connection to electricity ............................................................................................. 3
4. Device operation - function description ................................................................................. 6
4.1. Available features (depending on the version) ............................................................. 6
5. Installing the accessories ........................................................................................................ 7
5.1. MFP-2 floater (RNS-1) ............................................................................................... 7
5.2. SE-3 sensor (RNS-2) ................................................................................................... 7
5.3. SE-1 sensors (Niva-3) ................................................................................................. 8
A. Declaration of conformity ................................................................................................... 8
Read these instructions carefully before installing, commissioning and using
this product
MPNT0417 v1.0EN (02/01/2020)
OPERATING INSTRUCTIONS
RNS-1, RNS-2 and
NIVA 3 Module
level regulation module
Réf : PF10L006 / PF10L002 / PF10L009

Advertisement

Table of Contents
loading

Summary of Contents for ccei RNS-1

  • Page 1: Table Of Contents

    4. Device operation - function description ................. 6 4.1. Available features (depending on the version) ............. 6 5. Installing the accessories ......................7 5.1. MFP-2 floater (RNS-1) ....................7 5.2. SE-3 sensor (RNS-2) ....................7 5.3. SE-1 sensors (Niva-3) ....................8 A.
  • Page 2: Technical Specifications

    220 x 200 x 150 mm Protection factor IP-55 Depending on the model: • 1 MFP2 (SF140008) floater = RNS-1 Level sensor • 1 SE-3 (SF140005) sensor = RNS-2 • 3 SE-1 (SF140017) sensors = NIVA-3 1 24V AC - 6VA output for solenoid...
  • Page 3: Pack Contents

    For safety reasons and in compliance with the NF C15-100 standard, the box in which the RNS-1, RNS-2 and NIVA 3 Module is installed must be • either at 3.50 m from the pool edge. This distance takes into account the dis- tance around obstacles.
  • Page 4 OPERATING INS- RNS-1, RNS-2 and NIVA 3 Module v1.0EN TRUCTIONS A. Pump prohibition (see below for more details) B. 24V output for solenoid C. Level sensor connection supplied with the box. The connection differs depending on the level sensor being used. The lower part of the image (C)
  • Page 5 • B: filtration contact installed in the box • C: wire to add to connect the pump prohibition to the box RNS-1, RNS-2 and NIVA 3 Module Disconnect the wire or wires arriving on the A1 terminal block from the filtration contact and send them to a terminal on the "Pump prohibition"...
  • Page 6: Device Operation - Function Description

    Similarly, the solenoid will close when the level has stabilised over the threshold for 5 seconds. 4.1.2. Pump prohibition output The RNS-1, RNS-2 and NIVA 3 Module has a Pump prohibition output that is used to prevent the pump from running if there is not enough water.
  • Page 7: Installing The Accessories

    OPERATING INS- RNS-1, RNS-2 and NIVA 3 Module v1.0EN TRUCTIONS 5. Installing the accessories 5.1. MFP-2 floater (RNS-1) The MFP-2 floater is fixed in the skimmer. Pre- ferably use silicone or neoprene adhesive and make sure not to block the removal of the filte- ring basket.
  • Page 8: Se-1 Sensors (Niva-3)

    (A), or stops after 3 hours (see Fault section) A. Declaration of conformity CCEI S.A.S (FR 47 40 35 21 693) declares that product RNS-1, RNS-2 and NIVA 3 Module is compliant with the safety and electromagnetic compati- bility requirements of European directives E.M.C (2014/30/UE), Low voltage...

This manual is also suitable for:

Rns-2Niva 3Pf10l006Pf10l002Pf10l009