Ruijie Cloud Class RCD6000E V3 (V4.XX) Series Server User Manual...
Page 2
Thank you for using Ruijie products. Ruijie strongly recommends that you carefully read this manual before using the device. If you perform operations on the device without reading this manual, Ruijie assumes no responsibilities for any losses incurred. In addition, Ruijie may make small adjustments to the device to enhance device performance, which may result in slight differences between operations described in this manual and actual ones.
Page 3
To ensure safe and stable running of the Ruijie Cloud Desktop (RCD) server, correctly connect the power cords of the RCD server and peripheral devices to the power distribution device (branch connection line or socket). Check that the power distribution device is correctly grounded before installation, and ensure that the 3-pole power cord delivered with the device be used.
1 Introduction 1.1 Overview Ruijie Cloud Class (RCC) RCD6000E V3 series servers change the traditional classroom structure and achieve an unparallel combination of desktop virtualization and computerized classroom, to provide rich teaching approaches based on courses and deeply optimize teaching. The RCD servers adopt centralized and unified management to improve the efficiency by 90%, and offer multiple interaction means to enliven the classroom atmosphere.
Page 5
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual capacity Unit memory 4 GB, 8 GB, 16 GB, and 32 GB (RDIMM) size Slot quantity Front: 12 x 2.5/3.5-inch SATA hot-swapping hard disk Standard 3 x 240 GB SSD...
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual 1.3 Appearance 1.3.1 Front Panel Description Front panel 1 Hard disk status indicator Hard disk activity indicator Hard disk drive Front panel 2 ● Buttons and Indicators on the Front Panel...
Page 7
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual Front Panel Indicators Indicator Type Color Status Description Hard Disk Activity Hard Disk Status Indicator Indicator Green Green Idle: Solid on The hard disk drive is Solid on Hard disk indicator Reading: Blinking identified or located.
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual indicator example, severe temperature/voltage state) occurs. A critical or unrectifiable fault (for example, Solid on critical/unrecoverable temperature/voltage state) occurs. 1.3.2 Rear Panel Description Power device interface 2 (filler panel) Serial port...
Page 9
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual Description AC power indicator 2 (unavailable) Speed indicator of GE network interface 1 Link/Activity indicator of GE network interface 1 Speed indicator of GE network interface 2 Link/Activity indicator of GE network interface 2...
GE network interface 1 is connected with a speed of 10 Mbit/s. 1.4 Hard Disk Slots and Indicators On Ruijie Cloud Class RCD V3 series servers, the front hard disk interfaces are compatible with 2.5/3.5-inch SATA hard disks. Hard Disk Slots Slot...
Page 11
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual Using memory modules of different models will affect system stability and even result in startup failures. The table below provides rules for installing memory modules. Quantity memory installed √ √...
1.6 Power Module Ruijie Cloud Class RCD6000E V3 series servers provide two power slots each, and support hot swap and 1+1 redundancy. One system power module is configured by default. A single power module can output power up to 750 W.
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual 2 Installation Preparations 2.1 Safety Suggestions To prevent personal injuries and device damage, read through safety suggestions in this document carefully before RCD server installation. Safety suggestions below do not cover all possible dangerous situations.
RCD server and severely affecting its service life. The requirements of Ruijie RCD servers for the temperature and humidity are as follows: Temperature: 5° C to 35° C Relative humidity: 20% to 80% The temperature and humidity of the operating environment of the device are measured at 1.5 m above the...
Page 15
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual 2.2.4 Cleanliness Requirements Dust is hazardous to device running. Dust accumulated on the device will cause electrostatic adsorption and result in poor contact at metal contacts. Especially, when the indoor relative humidity is low, accumulated dust is more apt to cause electrostatic adsorption, which will not only shorten the service life but also cause communication failures.
Ruijie RCD server is equipped with fans. Its heat dissipation principle is as follows: Cold air around the housing is sucked into the device via air vents and hot air is exhausted from the rear side of the housing via the fans. Therefore, at least 15 cm space needs to be reserved around the air vents, for ease of heat dissipation.
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual The distance between square hole strips on the left and right sides of the 19-inch standard cabinet is 465 mm. The figure below shows a 19-inch standard cabinet. The distance between the square hole strip on the rack column and the outer side of the front cabinet panel is greater than 180 mm, the thickness of the front cabinet panel is smaller than 25 mm, the available space is greater than 155 mm, and the cabinet depth (distance between the front and rear panels) is greater than 1000 mm.
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual 3 Installation Procedure Ensure that you have read through Chapter 2 carefully and requirements in Chapter 2 are all met. 3.1 Installing Guide Rails 1. Horizontally place the guide rail in the installation position on the cabinet, hook the rear end of the guide rail to the hole on the cabinet, and fasten the positioning screws on the front end to corresponding positions.
Page 19
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual Uplift the clips marked with 1 in the following figure on the guide rails on both sides, and push the server into the cabinet in the direction indicated by the arrow marked with 2 in the following figure.
Ruijie Cloud Class RCD6000E V3 (V1.XX) Series Server User Manual 3.3 Connecting Cables Connect the power cord delivered with the device to a power supply. Insert the plug of the power cord into a power strip. Ensure that the main power supply is disconnected before the power plug is inserted.
The RCD server restarts irregularly during running. Collect BMC logs and check whether a memory ECC error occurs. Log in to the Web page to collect logs and send them to Ruijie technical support personnel. 4.4 Fans Generate Loud Noise During Running Fault symptom: Fans generate loud noise during running of the RCD server.
Page 22
Check whether sufficient space for heat dissipation is reserved on the four sides of the RCD server. Check whether there is accumulated dust on the front panel of the RCD server. Collect the fan speed and CPU temperature via the Halo tool or BMC Web system. Then, send the information to Ruijie technical support personnel.