Ruijie Cloud Class RCD V3 (V1.XX) Series Server
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cloud Class RCD V3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ruijie Cloud Class RCD V3 Series

  • Page 1 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual...
  • Page 2 Thank you for using Ruijie products. Ruijie strongly recommends that you carefully read this manual before using the device. If you perform operations on the device without reading this manual, Ruijie assumes no responsibilities for any losses incurred. In addition, Ruijie may make small adjustments to the device to enhance device performance, which may result in slight differences between operations described in this manual and actual ones.
  • Page 3  To ensure safe and stable running of the Ruijie Cloud Desktop (RCD) server, correctly connect the power cords of the RCD server and peripheral devices to the power distribution device (branch connection line or socket). Check that the power distribution device is correctly grounded before installation, and ensure that the 3-pole power cord delivered with the device be used.
  • Page 4: Specifications

    1 Introduction 1.1 Overview Ruijie Cloud Class (RCC) RCD V3 series servers change the traditional classroom structure and achieve an unparallel combination of desktop virtualization and computerized classroom, to provide rich teaching approaches based on courses and deeply optimize teaching. The RCD servers adopt centralized and unified management to improve the efficiency by 90%, and offer multiple interaction means to enliven the classroom atmosphere.
  • Page 5 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual configuration 16 GB x 6 16 GB x 5 16 GB x 4 capacity Unit memory 4 GB, 8 GB, 16 GB, and 32 GB (RDIMM) size Slot quantity Front: 8 x 2.5/3.5-inch SATA hot-swapping hard disk...
  • Page 6: Front Panel

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual 1.3 Appearance 1.3.1 Front Panel Description Front VGA interface Front USB3.0 interface Clip for fastening the RCD server to a cabinet Front hard disk slot CD-ROM drive (unavailable for this model)
  • Page 7: Rear Panel

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual System fault indicator and button LCD-equipped management module interface System fault indicator Memory fault indicator Fan fault indicator Power fault indicator System overheat indicator Network status indicator 1.3.2 Rear Panel ...
  • Page 8: Memory Module Installation

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual 1.4 Hard Disk Slots and Indicators On Ruijie Cloud Class RCD V3 series servers, the front hard disk interfaces are compatible with 2.5/3.5-inch SATA hard disks.  Hard Disk Slots...
  • Page 9 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual The table below provides rules for installing memory modules. Quantity of Memory Installed √ √ √ √ √ √ √ √ √ √ √ √ CPU0_DIMM_A0 √ √ √ √...
  • Page 10: Power Module

    1.6 Power Module Ruijie Cloud Class RCD V3 (1.XX) series servers provide two power slots each, and support hot swap and 1+1 redundancy. One system power module is configured by default. A single power module can output power up to 800 W.
  • Page 11: Installation Preparations

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual 2 Installation Preparations 2.1 Safety Suggestions To prevent personal injuries and device damage, read through safety suggestions in this document carefully before RCD server installation. Safety suggestions below do not cover all possible dangerous situations.
  • Page 12: Installation Environment Requirements

    RCD server and severely affecting its service life. The requirements of Ruijie RCD servers for the temperature and humidity are as follows:  Temperature: 0° C to 40° C ...
  • Page 13 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual The temperature and humidity of the operating environment of the device are measured at 1.5 m above the ground and 0.4 m in front of the RCD server rack when no protection plate is used in front of and behind the RCD server rack.
  • Page 14: Anti-Interference Requirements

     Ruijie RCD server is equipped with fans. Its heat dissipation principle is as follows: Cold air around the housing is sucked into the device via air vents and hot air is exhausted from the rear side of the housing via the fans.
  • Page 15: Cabinet Installation Requirements

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual 2.3 Cabinet Installation Requirements If the RCD server is to be installed inside a cabinet, check that the cabinet meets the following conditions: A 4-column 19-inch standard cabinet is used.
  • Page 16: Installation Procedure

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual 3 Installation Procedure Ensure that you have read through Chapter 2 carefully and requirements in Chapter 2 are all met. 3.1 Installing Guide Rails A guide rail is composed of an outer rail, a middle rail, an inner rail, and two fasteners.
  • Page 17 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual Determine the hole position for installing the front fastener on the cabinet, align the square locker and blue round button on the front fastener with holes on the rack rail of the cabinet, push the guide rail in the direction indicated by the arrow marked with 1 in the figure until the square locker is completely snapped into the hole, and then push the pin marked with 2 in the figure inwards until it is in place.
  • Page 18 Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual Repeat steps 2 and 3 to install the other guide rail. Stretch the inner rails completely in the direction indicated by the arrow shown in the figure. Ensure that guide rails on both sides are in the same horizontal line.
  • Page 19: Connecting Cables

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual After pushing the server into the cabinet, tighten screws on the left and right handles of the server. 3.3 Connecting Cables  Connect the power cord delivered with the device to a power supply.
  • Page 20: Verifying Installation

    Ruijie Cloud Class RCD V3 (V1.XX) Series Server User Manual  Connect the network cable with the standard RJ45 connector to the system network. Ensure that the power cord delivered with the device be used, to prevent safety accidents. 3.4 Verifying Installation...
  • Page 21: Common Faults And Troubleshooting

     Collect BMC logs and check whether a memory ECC error occurs.  Log in to the Web page to collect logs and send them to Ruijie technical support personnel. 4.4 Fans Generate Loud Noise During Running Fault symptom: Fans generate loud noise during running of the RCD server.
  • Page 22 Check whether there is accumulated dust on the front panel of the RCD server.  Access the TUI screen of the RCD server, press F2, Select System Information and Running State to collect the fan speed and CPU temperature. Then, send the information to Ruijie technical support personnel.