Symptom
Probable Cause
Action
634
Unable to write to diskette
1.
Check that the correct
file
diskette is in the control
unit. Press reset and retry
635
Diskette not ready
the operation.
2.
If the problem still exists.
follow the local procedures
for reporting problems
with the control unit.
636
Diskette file locked (File is
1.
Press reset and wait until
being used by another
the other operator is
operator.)
finished before trying
again.
637
Diskette file overflow
1.
Press reset and try again.
2.
If the problem still exists.
638
Not able to read the diskette
follow the local procedures
file
for reporting problems
with the control unit.
639
Diskette file not locked
640
Wrong diskette in control
1.
Check that the correct
unit
diskette is in the control
unit. Press reset and retry
the operation.
2.
If the problem still exists.
follow the local procedures
for reporting a problem
with the control unit.
641
Error queue overflow
1.
Press reset and try again.
2.
If the problem still exists.
follow the local procedures
for reporting a problem
with the control unit.
650
3290T
1.
Turn the power off and
then on again.
to
2.
If the problem still exists.
654
contact your local IBM
representative.
657
3290T
1.
Turn the power off and
then on again.
to
2.
If the problem still exists.
699
contact your local IBM
representative.
PROG700
Host
1.
Press reset and retry the
operation.
to
2.
If the problem still exists.
PROG799
contact your host support
programmer.
Any other problem
3290T
Go to 'Problem Analysis
Procedures' on page 17.
Figure 2 (Part 3 of 3). Problems That Occur While Using the 3290 T