Secam Color Circuit Adjustment; Purity - JVC TM-41 EG Service Manual

Colour video monitor
Table of Contents

Advertisement

3.3
SECAM
COLOR
CIRCUIT
ADJUSTMENT
1.
Test Equipment and Tools
Oscilloscope
SECAM color bar generator
VTIVM
Insulated adjusting rod
2.
Adjustment Steps
1) Supply a SECAM color bar signal.
2) Connect oscilloscope probe to TPS and, as shown
in Fig. 3-5, adjust the core of T3 to align the peaks
of the waveform.
Fig. 3-5
3) Disconnect
the
grey
receptacle
wire
from
TRC-
5210A.
4) Connect VTVM
between TP6 (+) and TP? (—).
Adjust the core
of T04
for maximum
(approx.
1 Vp-p) at both ends, At this time, confirm normal
color bar phase,
5) Observe
the waveform
at the coupling point be-
tween
L710017 and C1005. Adjust the core of TO6
'to set the retrace evel as shown in Fig. 3-6
LL
A
(B)
on
rir
Fig. 3-6
6) Observe
the waveform
at the coupling point be-
tween
11002 and C1G05. Adjust the core of TOS
to set the retrace level as shown in Fig, 3-7.
3-2
Fig. 3-7
3.4
PURITY
1)
Display a monochrome pattern
2) As viewed from the back (see Fig. 3-8}, turn the
magnet lock counter-clockwise to loosen it.
Purity magnet
6 pole convergence
Yoke retaining clamp
Yoke iocking ring
Def. yoke
4 pole convergence
Fig. 38