Setting of the end positions
4.5.1. Semi-automatic setup-mode, deletion and semi-automatic setting of the end
positions
in operation bottom position, top stop WITH release
When the movement is interrupted twice during operation, the system is in semi-automatic
setup-mode. The motor will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption, until the motor is automatically switched off.
Operation
Operation with
with switch
setting switch
or
Drive
E
1 s
STOP
E
STOP
STOP
STOP
Press the E button of the setting switch for
1 second. Both limit positions already set will
be deleted.
Note: Not required for the initial installation or
after resetting to factory defaults.
Move the motor with the UP or DOWN button
downwards to the requested lower end limit.
Run against the limit stop at the top without
stopping; the motor stops automatically. The
correct direction of rotation assignment has
been made. Perform a test run: The motor
moves up against the limit stop and relieves
shortly.