3) Procedure
Remove three top cabinet holding screws
Remove the ring core from the cabinet.
Remove the top cabinet from the bottom cabinet.
Remove the top cabinet from the drawer. Unfasten the transformer
and drawer connectors.
Remove the transformer holding screw.
Remove the transformer cover from the drawer.
Get the bottom cabinet ready.
Insert the wire of the drawer solenoid microswitch in the clamp and
install the clamp to the shield plate. Note that there is a microswitch
wire provided for use with the UK version model.
Note:
Even for the drawer with no microswitch it is necessary to
Clamp
install a clamp to the shield plate without fail.
This means that two clamps must be installed without
exception.
|
Place the shield plate under the back of the bottom cabinet, and
Shield plate unit
Rubber footing
Washer
Screw for rubber
fasten the rubber footings with screw at four locations and ata
center.
O
footing
Screw
Install the transformer cover to the rear right of the bottom cabinet
Screw
—_h, won,
and fasten the transformer with screws. (Use new screw for the
ER-1911S)
Fasten the grounding wire.
Fasten the ring core
Screw
(Use new screw and nut.)
Nut
Fasten the top cabinet with three screws. Use a new screw for the
Screw, printer
12
13
14
1
printer of the ER-1911S and for the one in the rear left.
pa
fe
Screw, rear left
4) Setting
Master reset
While pressing the journal feed key, rotate the MODE switch from SRV2 to SRV1 position.
Route the solenoid microswitch connector through the square hole
beneath the bottom cabinet.
Replace the top cabinet to the bottom cabinet. Fasten the trans-
former and drawer connectors as this point.
|
Remove the grounding wire from the top of the drawer.