Before you start

Initial settings

Run Calibration (recommended)
Calibration ensures accurate weight
detection by the washing machine. Make
sure the drum is empty before running
Calibration.
1. Turn the washing machine off.
2. Press Power while holding down Temp.
and Delay End simultaneously. The
washing machine will turn on and "Cb"
will appear on the display.
3. Press Start/Pause to start Calibration
Mode.
4. The drum will rotate clockwise and
counter-clockwise for about 3 minutes.
5. When Calibration Mode is complete,
"End" appears on the display and
the washing machine will turn off
automatically.
6. The washing machine is now ready for
use.
24 English