Download Print this page

Honeywell X Series Manual page 7

Smoke and heat alarms
Hide thumbs Also See for X Series:

Advertisement

Smoke and heat Alarms
Multi-Criteria
Detection
Optical smoke
alarms use an
optical chamber
to
"see" the
smoke.
Certain fire
types
are
recognized with some
delays only.
Multi-criteria detection
therefore
ads a
thermal sensor and
use
an intelligent algorithm
to
improve
reaction speed, and
reduce
the
number
of false
alarms.
Low
Profile Design
Honeywell's low
profile
design utilising
rounded
corners,
sleek
round
design
and low profile height
make
the unit
seem
a lot
smaller
than it
really
is.
Honeyruell have
employed design agencies
and
end
user
market
research
to
select
the
best
suitable concept.
Full
Ten
Year Lifespan and Warranty
Honeywell's full
product
lifespan
warranty
is
one of
the most
comprehensive
in
the industry
This is backed up
with
more than 50 years of fire alarm experience
producing some of
the most
reliable alarms
in
the
market.
Honeyvvell is
one
of
the
few
companies
in
the
market
to
offer
a
full ten year lifespan and ten year
warranty
on
its smoke
and
heat alarms.
lndependent 3rd
Party
Certification
and Q-Label
All
residential
smoke alarms
being
sold
in
the
EU
must
be
cedified by
a 3rd
party,
for
example
VdS, against
EN14604
which
is
the standard for
residential
smoke
alarms.
This
sets
the minimum
requirements
for smoke
alarms
to
be
sold, whether it
is
for
DIY
or
professional use. The
Q-Label
is a
voluntary
additional 3rd party certification, which
is granted
to
high
quality smoke
alarms.
Smoke
alarms
with the Q-Label
are
tested for long-life,
minimised
false
alarms,
increased
protection
against
adverse
environmental
conditions
and
have a
sealed
battery
with at least
10
years
lifetime.
CE
Mark
The CE
mark
affixed
to this product confirms
its
compliance with the
European
Directives
which apply to the product and, in
particular,
its compliance with
the harmonised specifications of standard EN
14604 relating
to
Construction
Products
Directive
89/1
06/EEC.
BSI
Kitemark
The
BSI
Kitemark
is a
product
or
service certification
mark
that shows it
has
been
tested independently
and
audited
to
ensure
it
meets
the appropriate
standards of quality and
safety.
NF
Mark
The NF
-
Smoke
Alarm
Devices
mark provides
assurance as
to safety
and
consistent quality inspected by experts. Through its rigorous
and exhaustive
inspections (holdels quality
management
system, product
inspections,
audits and monitoring tests,
etc.),
the
NF
mark
represents a
comprehensive
guarantee
for consumers that the certified products
are
compliant.
The
NF
-
Smoke
Alarm
Devices
mark confirms the product's compliance with
certification
rules NF 292.
Automatic Self-adiustment
/
Self Checks
Honeywell's smoke
and
heat alarms have been
fitted with
an automatic self
test
function which
ensures
the
unit
is
functioning
properly. Every ten seconds,
the
unit
tests
critical systems
to
ensure accurate alerts are delivered rapidly once a
fire
is
detected.
Clearly Visible
Alarms
Honeywell
have
integrated
a set
of
clearly
visible
LED
lights
into
the perimeter
of the unit,
ensuring
the
alarm
can
be seen
from
all angles- This
feature
greatly
helps people who
have hearing
troubles so
may
not
hear
the
alarm.
Heat
Alarms
Combining fast
levels
of detection with
minimum
false
alarms,
the
Honeywell
XH100
Heat
Alarm
is
best suited
to
areas
with
high levels
of dust
or fumes,
such as kitchens and
garages.
Dirt Compensation
Honeywell's unique dirt compensation ensures that nuisance alarms are kept
to
a
minimum. By not confusing dust with smoke, the X-Series smoke and heat alarms
only sound when a hazard
is
detected.
X-Series Alarms
Sealed Housing
Honeywell's X-Series alarms
all
have sealed
housings.
lt
protects the
electronics from
adverse environmental
conditions
like
humidity,
and
improves
reliability and
lifetime. We have been
successfully
using
this
technology for
many years in our
commercial smoke
alarms,
which
are
being used
in harsh
conditions
like warehouses.
Alarm
Hush
There
might
be situations where
the
unit is
in
full alarm, and you
want
to
mute
the 85dB
loud alarm sounder, e.g. when the
situation
is under
control.
Pressing
the
button on
the
unit will mute
the
sounder
for
5
minutes, whilst the alarm light
will
keep on flashing as long as
the
alarm
detects
a
threat.
Fault Hush
A
typical fault occurs
when
the
alarm
warns of
an
almost depleted
battery. The alarm
will start
to
bleep once
per
minute accompanied by
a
flashing fault
light. The
Fault
Hush allows you
to
mute the sounder for
24
hours,
giving
you
time
to
address
the fault.
lf
you wish
to
restart
the
24
hour
timer
in
the morning, you can
press
the button
a
second
time.
Reduced Sound Level Test
Alarms
need
to
be
tested
regularly,
to
ensure
they
are
working
properly.
After
pressing
the button, the
alarm
will start its internal self-test, flash
all
lights and sounding the
buzzer. Honeywell has
reduced the sound
level
for this test function considerably from the full
alarm level
of 85dB. lt
still
tests the
alarm,
but your
ears are
being protected.
BTW: By pressing
the
alarm
for
more
than 3 seconds, the full
alarm level
will
sound.
Tamper-Proof
Many
professional
landlords
want
to
ensure
that installed
alarms
cannot
be
stopped from
normal
operation
by
the end-user.
ln
the
past,
tenants
have
often
removed
the
batteries
to
use
them for instance
in TV
remote
controls.
Honeywell's X-Series alarms all have
sealed
batteries,
which
cannot
be
removed by the
end-user.
Also, once
installed, a
tool
like a
screwdriver
is required
to switch the
unit
off or
remove
it.
Maintenance Free Operation
All
Honeywell X-Series alarms have batteries,
which
last the
whole
lifetime
of
the alarms.
No
additional cost for batteries or
labour
cost to
replace
them
occur. The same
applies
for
the
CO
sensor: lt
lasts
the
whole
lifetime
of
up
to
10 years. The
only
required maintenance is
the
occasional cleaning of the product.
lnterlink
Interlink means
the
connection of several alarms
to
an alarm system. So
if
one
unit goes into alarm, all other units will
sound
as well. This improves
considerably the safety especially in larger
accommodations
like
multi-
story houses. All X-Series alarms
can
be upgraded,
to
connect wirelessly.
All mains
powered
Honeywell X-Series alarms can be linked by wire.
Battery Back-up
l\/lains
powered alarms can be
effected by
power outages. Therefore,
all Honeywell mains powered X-Series alarms
are
fitted with
a battery
backup.
t-i
,*
c7
How
we
add value

Advertisement

loading

This manual is also suitable for:

Xh100Xs100Xs100t