Download Print this page

Harman Kardon AVR20MKII Technical Manua page 17

Hide thumbs Also See for AVR20MKII:

Advertisement

450 kHz
999 kHz
AC voltmeter to | T805
Maximum
4
(400 Hz, Mod.)
TAPE OUT jack. | (IFT)
reading
5
999 kHz
999 kHz
Same as
VR801
FL display 'TUNED"
{400 Hz, Mod.)
Step 1.
Indication on receiver
with AM SSG Output
level of 800 upV/m
2" (60 Cm)
a
Tape out
Receiver
|
|
Tuner
|
Front-End
|
|
Direct Coupling
AM Alignment Connection
4, FM IF Alignment
Preparation
1. Signal Generator output should be no higher than necessary to obtain an optimum output reading.
2. Switch Press to FM.
3. Signal generator deviation : 40 kHz.
Signal
Receiver
.
'
:
Step
Generator
Frequency
Equipment
Adjustment
Adjust
Frequency
Display
Connection
Point
for
1
98.0 MHz
98.0 MHz
DC Volt meter to
T803
Zero reading on DC
(1 kHz, Mod.)
R809 (PCB10)
|
volt meter.
98.0 MHz
98.0 MHz
Distortion
T804
Minimum
2
(1 kHz, Mod.)
meter to
distortion
TAPE OUT jack |
98.0 MHz
98.0 MHz
Same as
VR802
FL display 'TUNED'
3
(1 kHz, Mod.)
Step 1
:
Indication on
receiver with FM
SSG output level of
10 uV/m

Advertisement

loading