Measurement And Adjustment - Teac A-3440 Service Manual

Hide thumbs Also See for A-3440:
Table of Contents

Advertisement

| e Before performing maintenance on this deck, thoroughly clean and demagnetize the entire tape
path. TEAC maintenance equipment to be used:
TEAC TZ-261 A/B for cleaning
TEAC E-3 or equivalent for demagnetizing
¢ Service Data were determined using TEAC YTT-Series Test Tape.
e The deck must be matched to the voltage and frequency of your locality.
Refer to Power Requirement and Consumption chart (Item 2-1, Specifications Section).
eMost amplifier checks and adjustments can be made from the bottom with the (bottom) metal
panel removed.
© Outlined procedures refer only to channel 1, the same procedures also apply to channel 2, 3 and
oe
PLAY
BIAS
OUT PUT
METER
SOURCE
REC
BIAS
RE
AL
CAL
REC/PLAY PCB
CAL
LEVEL
5
CH!
CAL TRAP
C,
(8) ie
(7): DUMMY
COIL.
T-1278
Fig. 8-1
Adjustment Locations and Adjustment Points
16