N A T U R A L L Y C O O L E R N A T U R A L L Y C O O L E R Installation and Operating Manual Installation and Operating Manual EXH Series EXH Series Evaporative Air Coolers Evaporative Air Coolers...
Index INDEX SAFETY......................1 OPERATING INSTRUCTIONS Thermostat Range..................2 Using the Remote Control...........3 SENSORTOUCH Using the Wall Control............7 SENSORTOUCH Maintenance....................9 Pre-Assembly Inspection................10 INSTALLATION INSTRUCTIONS Installation Details..................11 Water Installation................... 12 Electrical Installation..................13 Wall Control................13 SENSORTOUCH Remote Control..............14 SENSORTOUCH Testing the cooler...................16 Installation Checklist..................
Safety Use only the power supply voltage SAFETY INSTRUCTIONS WATER PUMP shown on the motor/cabinet Important Safety Instructions and The water pump is supplied with this nameplate. Warnings cooler and is factory fitted into its WARNING: The warnings and safety correct location.
Thermostat Range REMOTE CONTROL AUTO COOL SPEED ECONOMY ILL239-D ILL1140-A SENSORTOUCH SENSORTOUCH Remote Thermostat Control Wall Mounted Thermostat Control (remote control) (wall control) ®...
Using the SENSORTOUCH Remote Control SETTING THE CLOCK MANUAL MODE Set the clock on the remote control before Once either COOL or VENT has been proceeding with any other programming. selected, the remote control will maintain a constant fan speed. This is indicated by the The clock can only be set with the remote bar graph in the centre of the display.
Page 6
Using the SENSORTOUCH Remote Control AUTO TIMER MODE (4) Setting the OFF time minutes Press the button. The minutes Programming the timer must be performed displayed will start flashing and the word OFF before AUTO TIMER can be activated. This will appear.
Page 7
Using the SENSORTOUCH Remote Control ECONOMY MODE During this operation the word PRE-COOL will be displayed on the remote control’s screen. Selecting the ECONOMY mode limits the maximum available cooling or ventilation and reduces the power used by up to 20%. The MANUAL ECONOMY function can be used in either COOL...
Page 8
Using the SENSORTOUCH Remote Control The high salinity setting is designed to operate the cooler at a maximum safe salinity level to AUTO COOL maintain a normal working life. It also results in a minimum usage of water. SPEED MANUAL BATTERY LOW COOL ILL1106-A...
Using the SENSORTOUCH Wall Control In Manual mode the cooling level can be STARTING YOUR COOLER manually adjusted. button turns the air cooler on and In Manual mode, press to choose off. between circulating cool air or uncooled air. There are two modes of operation to choose When “Cool”...
Page 10
Using the SENSORTOUCH Wall Control TIMED AUTOMATIC STOP DRAIN VALVE You can also set the air cooler so that it will This air cooler is supplied with an automatic drain that performs two primary functions: turn off after a set number of hours. 1.To set a delayed stop time, press with the cooler RUNNING.
Using the SENSORTOUCH Wall Control • Turn off power switch inside the cooler. Display Number Drain Delay Time (Fig. A) • Check and clean the lid water spreaders 4 hours (Fig. C) 1 Day 2 Days 3 Days STANDARD 4 Days Press to select your desired delay time.
Pre-Assembly Inspection PRE-ASSEMBLY INSPECTION Check that the correct cooler has been supplied. The cooler should have the following parts:- (Check the parts are inside the cooler by removing a cooling pad frame.)
Installation Details UNPACKING THE COOLER Keep the cooler away from heater NOTE! It is recommended that a strip flues, exhaust vents (especially of foam or sealant is applied to the Cut and remove the shrink wrap from kitchens) and sources of ignition. upper flange on the roof jack before around the cooler.
Installation Details INSTALLING THE INLET SOLENOID VALVE Fit the inlet solenoid valve under the pan as shown (Fig 14). Insert the solenoid valve cable through the hole (behind the drain valve) and connect the plugs to the solenoid valve. (Fig. 13) Make sure the cable is fitted to the groove underneath the The sump of the pan is designed to pan.
Installation Details INSTALLING THE DRAIN KIT after making connections and clamping the conduit cable. It is a requirement of Seeley International - Never drain the Ensure that all electrical connections water directly on to the roof (This are tight. Loose connections will cause applies to all types of control/drain overheating that may lead to machine systems).
SENSORTOUCH Remote Control • Do not locate in the direct airflow of Other Options for Mounting Correct plug orientation the duct outlets. Receiver • Do not locate in strong drafts or in The standard installation arrangement dead spots such as cupboards / will satisfy the majority of applications.
Page 17
SENSORTOUCH Remote Control (3)...Interference from nearby COMMISSIONING USING THE The "Red (bottom) LED" indicates transmitters (e.g. mobile phone, AM the status of the WaterManager REMOTE CONTROL radio, Television, RF security measurement circuit and will Take the remote control to the roof and systems).
Testing the Cooler TESTING THE COOLER Note! The control box cover will only LED 3 when on (glows green), open and close with the ON / OFF indicates the motor is rotating at the Once you are satisfied that the cooler switch in the "OFF"...
Installation Checklist Owners Name:______________________ Cooler level and secure. __________________________________ All roof work properly sealed. Telephone:_________________________ Address:___________________________ Ductwork and air distribution checked and outlets correctly set. __________________________________ All wiring complete. __________________________________ Dealer:____________________________ Control switch correctly installed. __________________________________ Motor and pump correctly plugged into sockets. Installer:___________________________ __________________________________ Drain/overflow fitting correctly installed.
Installation Troubleshooting PROBLEM PROBABLE CAUSE SUGGESTED REMEDY Inadequate Cooling Under-sized cooler. Replace with larger cooler. Replace with larger ducts. Under-sized ducts. Clogged or dirty cooling pads. Clean or replace pads. Dry pads or lack of water while Check water distribution system for cooler is operating.
Page 21
Installation Troubleshooting PROBLEM PROBABLE CAUSE SUGGESTED REMEDY Pump runs but no water circulation. Insufficient water in pan. Adjust float level. Pump runs but pads lack water. Water hoses blocked. Check and clean out blockage. Pump strainer blocked. Clean pump strainer. Float valve adjustment not correct.
Appendix A - Wiring Diagram BREEZAIR COOLER BREEZAIR COOLER DIRECT DRIVE FAN MOTOR ALL COOLER CONTROLLER COMPONENTS ARE PLUG (ELECTRONICS CONNECTED MODULE) 3 CORE POWER CABLE CABLING FURNISHED BY THE WALL DRAIN PUMP SALINITY SOLENOID MANUFACTURER CONTROLLER VALVE PROBE REMOTE CONTROL RECEIVER DISCONNECT SWITCH...
Page 24
Seeley International (Americas) Phone: 602-353-8066 Fax: 602-353-8070 Toll Free: 1-800-926-6824 www.convaircooler.com Evaporative Air Cooling Manual. Seeley International Pty Ltd, Adelaide, South Australia. ACN 054 687 035. As the policy of the company is one of continuous product improvement, all specifications are subject to change without notice. 846880-C US 0710...