Table of Contents

Advertisement

Available languages

Available languages

CAUTION
DO NOT DISCARD MANUAL!
IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS
INCLUDED.
SAVE THESE INSTRUCTIONS AND
LEAVE THIS MANUAL WITH ANY
PERSON RESPONSIBLE FOR USE AND
OPERATION.
ATTENTION
NE PAS JETER!
IMPORTANTES INSTRUCTIONS
D'UTILISATION ET D'ENTRETIEN
INCLUSES.
CONSERVEZ CES INSTRUCTIONS
ET LAISSEZ CE MANUEL À TOUTE
PERSONNE RESPONSABLE
DE L'UTILISATION ET DU
FONCTIONNEMENT.
WARNING
PLEASE READ THIS ENTIRE
MANUAL BEFORE INSTALLATION
AND USE OF THIS PELLET
FUEL-BURNING ROOM HEATER.
FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY
INJURY OR EVEN DEATH.
AVERTISSEMENT
VEUILLEZ LIRE CE MANUEL EN
ENTIER AVANT D'INSTALLER
ET D'UTILISER CET APPAREIL
DE CHAUFFAGE AUTONOME À
GRANULES, AFIN D'ÉCARTER LES
RISQUES DE DÉGÂTS MATÉRIELS,
DE BLESSURES CORPORELLES,
VOIRE DE MORT.
Get parts online at
www.CastleStoves.com
CAUTION
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIREMENTS FOR YOUR AREA.
ATTENTION
CONSULTER LES SERVICES DU BÂTIMENT OU D'INCENDIE LOCAUX
CONCERNANT LES RESTRICTIONS ET LES EXIGENCES D'INSPECTION
D'INSTALLATION EN VIGUEUR.
Operator's Manual
Serenity
Pellet Stove
Model 41278
GAS/OIL
RATIO
50:1
P/N: 41723
ECN: 14356
REV4: 06/16/2023
© 2023 Ardisam Inc.
All Rights Reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Serenity 41278 and is the answer not in the manual?

Questions and answers

Summary of Contents for CASTLE Serenity 41278

  • Page 1 Operator's Manual Serenity Pellet Stove Model 41278 CAUTION DO NOT DISCARD MANUAL! IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS INCLUDED. SAVE THESE INSTRUCTIONS AND LEAVE THIS MANUAL WITH ANY PERSON RESPONSIBLE FOR USE AND OPERATION. ATTENTION NE PAS JETER! IMPORTANTES INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN INCLUSES.
  • Page 2: Warnings And Safety Precautions

    INSTRUCTIONS THAT FOLLOW THIS SIGNAL • Maintain the stove according to directions and sched- WORD ARE NOT OBEYED. ule included in this Castle operator’s manual. • Ensure that anyone who uses the stove is familiar with all controls and safety precautions.
  • Page 3 Operator's Manual Serenity Pellet Stove WARNING WARNING PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL- HOT SURFACE ! DO NOT TOUCH! SEVERE BURNS BURNING ROOM HEATER. FAILURE TO FOLLOW MAY RESULT. CLOTHING IGNITION MAY RESULT. GLASS AND OTHER SURFACES ARE HOT DURING THESE INSTRUCTIONS...
  • Page 4 THE BUILDING CODES WILL TAKE PRECEDENT AND NOT PERMITTED. ANY FUELS NOT CERTIFIED BY MUST BE FOLLOWED. CONTACT YOUR LOCAL BUILDING CASTLE PELLET STOVES WHICH ARE BURNED IN INSPECTOR TO OBTAIN ANY NECESSARY PERMITS OR THIS STOVE WILL VOID THE WARRANTY.
  • Page 5 TO DETERMINE THE NEED FOR A PERMIT. THE MOVING PARTS OF THIS STOVE ARE PROPELLED BY HIGH TORQUE ELECTRIC MOTORS. THESE PARTS THE CASTLE PELLET STOVES PELLET STOVE IS CAN CAUSE SEVERE DAMAGE TO BODY PARTS DESIGNED TO BURN PELLET FUEL ONLY.
  • Page 6: Table Of Contents

    Operator's Manual Serenity Pellet Stove TABLE OF CONTENTS TABLE OF CONTENTS WARNINGS AND SAFETY PRECAUTIONS ......................................2-5 Table of Contents ...............................................6 REGISTRATION, SERVICE AND MAINTENANCE LOG ..................................7 INTRODUCTION................................................8 Burning Pellet Fuel ..............................................8 Automatic Safety Features ...........................................8 SPECIFICATIONS ................................................9 UNPACKING .................................................9 INSTALLATION ................................................10 Stove Placement ..............................................
  • Page 7: Registration, Service And Maintenance Log

    Record the model number and serial number in the space provided for easy reference. Fill out and mail the registration card located in the parts packet or register online at www.castlepelletstoves.com. Warranty is valid only if the completed registration is received by Castle within 30 days of purchase. OWNERSHIP RECORDS Dealer’s Name:...
  • Page 8: Introduction

    INTRODUCTION Clinkers Congratulations on your investment in quality. Thank you for your purchase on a Castle Pellet Stove. We have worked to ensure that • Impurities, such as silica (clinkers), will need to be this pellet stove meets the highest standards for usability and regularly cleaned and removed from the pellet stove.
  • Page 9: Specifications

    VOID STOVE WARRANTY. COMPLIANCE NOTE (1) Based on post 1982 home construction, requiring 35 The Serenity pellet heater, by Castle, meets the U.S. Environmental BTU/Hr. per Sq. Ft. Heat output will vary, depending Protection Agency’s emission limits for pellet heaters sold after on the brand, type and quality of fuel and the moisture May 15, 2020.
  • Page 10: Installation

    Operator's Manual Serenity Pellet Stove INSTALLATION It is recommended the stove be installed and serviced by WARNING authorized professionals who are certified by the National Fireplace Institute (NFI) as NFI Pellet Specialists. READ THIS ENTIRE MANUAL BEFORE YOU INSTALL Proper installation of this stove is necessary for safe and efficient AND USE THIS STOVE.
  • Page 11: Clearance To Combustibles

    Operator's Manual Serenity Pellet Stove Clearances To Combustibles NOTE: These are minimum clearances to combustible walls established by the ASTM testing lab. (SEE FIGURES 3, 4, 5, & 6.) 5" 5" 7" 5" Figure 3: Straight Installation Through Wall Figure 4: Corner Installation Through The Wall Vents 2"...
  • Page 12: Venting

    Operator's Manual Serenity Pellet Stove Venting Before venting, consult vent manufacturer’s specifications and CAUTION recommendations for all venting installations. The following installation guidelines must be followed to ensure DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE conformity with both the safety listing of this stove and to local SERVING ANOTHER APPLIANCE.
  • Page 13: Preferred Pellet Vent Termination Clearances

    Operator's Manual Serenity Pellet Stove Preferred Pellet Vent Termination Clearances • The stove vent must terminate on the outside of the building. Horizontal terminations must extend a minimum of 12” from the wall. Vertical terminations must protrude a minimum 24” from the roof surface. In addition, all clearances listed below must be met.
  • Page 14 Operator's Manual Serenity Pellet Stove Venting The Pellet Stove (See Figures 8 through 16.) CAUTION 33 Feet MAKE SURE PELLET STOVE IS VENTED CORRECTLY. (max.) DO NOT INSTALL FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. 30 Feet USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS.
  • Page 15: Outside Air Connection

    ROOM. NOTE: PVC pipe is NOT approved and should NEVER be connected to the stove. HINT: A Castle Pellet Stove air inlet will accept CAUTION automotive exhaust pipes and couplers If the air inlet is connected to the outside, it MUST be terminated with a vertical 90 bend (down) or with a wind hood.
  • Page 16 Operator's Manual Serenity Pellet Stove SIMPLE STOVE VENTILATION EXAMPLES wall termination clean-out fresh air inlet floor heat-resistant material —Outside Vertical Rise, Horizontal Termination Figure 10: Straight Installation venting pipe termination heat-resistant material wall fresh air inlet clean-out floor Figure 11: Straight Installation—Inside Vertical Rise, Horizontal Termination Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 17 Operator's Manual Serenity Pellet Stove COMPLEX STOVE VENTILATION EXAMPLES Vertical Cap 24” Minimum Storm Collar Roof Flashing Insulation must maintain clearance Vent must Ceiling Support/Fire Stop Spacer maintain clearance to combustibles “L” Vent Vent Clearance* Floor 3” Min. Protection Outside air may be drawn from a vented crawl space.
  • Page 18 Operator's Manual Serenity Pellet Stove CLASS A CHIMNEY RETROFIT Class A Chimney Storm Collar Roof Flashing Class A chimney must maintain clearances outlined in the chimney’s installation instructions (usually 2”) Class A Chimney Ceiling Support “L” Vent to Class A Chimney Adapter “L”...
  • Page 19 Operator's Manual Serenity Pellet Stove MASONRY FIREPLACE HEARTH STOVE Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone “L” Vent Flex Section 3” Lintel Outside air may be drawn 6” Min. from the ash cleanout. NOTE: you will probably need a short horizontal section here to clear the lintel and allow the hopper lid to open Figure 14: Masonry Fireplace Hearth Stove...
  • Page 20 Operator's Manual Serenity Pellet Stove ZERO-CLEARANCE (METAL) FIREPLACE HEARTH STOVE Cover Plate (non-combustible) Vertical Cap Seal the cover plate with silicone Storm Collar “L” Vent “L” Vent Flex Section 3” 6” Min. Figure 15: Zero-Clearance (Metal) Fireplace Hearth Stove Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 21 Operator's Manual Serenity Pellet Stove FREESTANDING MASONRY CHIMNEY Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone “L” Vent Flex Section “L” Vent Sections Vent Clearance* Clean-Out Access 6” Min. * Install a vent at clearance speci ed by the vent manufacturer Figure 16: Freestanding Masonry Chimney Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 22: Understanding Your Stove

    10. Scroll Down Button - Allows you to scroll down to choose items in the menu. Your Castle Pellet Stove utilizes a vertical auger fuel feed system that is operated by a microprocessor controlled digital circuit 11. Enter Button - Pressing “Enter” button allows you to board.
  • Page 23: Main Operation Controller Screen Display

    Operator's Manual Serenity Pellet Stove MAIN OPERATION CONTROLLER SCREEN DISPLAY Figure 19a: Main Operation Control Screen Figure 19a: Main Operation Controller Screen Display 1. Heating Mode: Displays operation mode - manual, temperature, or weekly. 2. Work Stage: Displays operational stage in which the stove is currently operating (e.g. ignite, heating, shutdown). 3.
  • Page 24: Component Status Screen Display

    Operator's Manual Serenity Pellet Stove COMPONENT STATUS SCREEN DISPLAY Figure 19b: Component Status Screen Figure 19b: Component Status Screen Display 1. On/Off State Indicator: Indicates if the stove is on and in operational mode or if it is in the process of shutting down. 2.
  • Page 25: Pre-Operation

    Before starting your Castle Stove, you will need to determine in which mode you would like to run the stove. The Serenity can operate in three modes: 1.
  • Page 26 Operator's Manual Serenity Pellet Stove room temperature is exceeded. This is sufficient for most users and has the benefit of preserving life cycle on the igniter. • Temperature Mode with Eco Mode: The stove will adjust heating levels to maintain the desired room temperature.
  • Page 27: Operation

    Operator's Manual Serenity Pellet Stove OPERATION After you have chosen the mode in which to operate your stove, WARNING press the ON/OFF button (4, Fig. 17) to start the stove ignite cycle. NEVER SHUT THE STOVE DOWN BY UNPLUGGING IT Start Up FROM THE POWER SOURCE.
  • Page 28: Setting Other Data On Your Controller

    Operator's Manual Serenity Pellet Stove 2. In the “WEEKLY SCHEDULE” screen, you can begin with NOTE: If you have set a particular schedule for a day and setting the operation times for Sunday. Press ENTER to would like to apply that to the rest of the days of highlight the hour and use the SCROLL UP and SCROLL the week, you can navigate to “All”...
  • Page 29 Operator's Manual Serenity Pellet Stove Setting The Room Blower Voltage To Set The Room Blower Voltage: 1. Press and hold the ENTER button. This will take you to The blower voltage (controlling the room fan) can be turned up the “SET DATA” screen. or down for each power level to regulate the amount of heat 2.
  • Page 30 Operator's Manual Serenity Pellet Stove Setting The Exhaust Voltage most situations. 4. Use the SCROLL DOWN button to scroll down to the IMPORTANT NOTE: “Exhaust Voltage” field and press ENTER. 5. Use the SCROLL UP or SCROLL DOWN to adjust voltage ADJUST THE AIRFLOW GATE BEFORE INCREASING level.
  • Page 31: Diagnostics

    Vacuum: Indicates there is sufficient vacuum and suction. DIAGNOSTICS POF: Indicates the proof of fire switch is activated. Your Castle Stove’s controller comes equipped with an on-board Room T: Indicates temperature being read by room temp diagnostics option that will let you test some components of your sensor.
  • Page 32: Maintenance

    Inspect gaskets around the door periodically. Replace any worn, frayed or compacted gaskets. Replace broken glass only with high temperature ceramic glass, available from Castle Pellet Stoves. SEE FIGURE 31. Stove Emissions Stove emissions should be visually checked on a regular basis.
  • Page 33: Daily Maintenance Tasks

    Operator's Manual Serenity Pellet Stove Daily Maintenance WARNING The surfaces of the stove may be hot. Always wear a protective glove, even when the stove is cool to the touch. Be sure to shut HOT SURFACES CAN CAUSE BURNS. NEVER the stove off and allow to cool for one hour before performing PERFORM CLEANING OR MAINTENANCE ON A HOT any maintenance or service tasks.
  • Page 34 Operator's Manual Serenity Pellet Stove In addition to daily maintenance tasks, use an ash vacuum to clean the inside of the firebox. Remove the firepot from the pot holder and vacuum beneath. Be sure to remove any ash from the incoming igniter tube. SEE FIGURE 35.
  • Page 35: Troubleshooting And Repair

    Serenity Pellet Stove TROUBLESHOOTING AND REPAIR WARNING At Castle, we build quality and durability into the design of our products; but no amount of careful design by us, and careful maintenance by you, can guarantee a repair-free life for your WHEN PERFORMING ANY INTERNAL stove.
  • Page 36: Troubleshooting Guide

    Operator's Manual Serenity Pellet Stove TROUBLESHOOTING GUIDE WARNING WARNING NEVER SERVICE OR TOUCH THE FEED AUGER WITH THE STOVE PLUGGED IN. UNPLUG STOVE AND LET COOL BEFORE PERFORMING ANY MAINTENANCE. HOT PARTS CAN CAUSE BURNS. NEGATIVE PRESSURE IN A HOME IS A SERIOUS ISSUE.
  • Page 37 Operator's Manual Serenity Pellet Stove PROBLEM CAUSE SOLUTION Fuel not feeding, vacuum and Auger is obstructed Remove auger from housing and clean obstruction first. hopper lid signal present on the Auger not working Enter the diagnostic area in the controller and highlight the control.
  • Page 38: Illustrated Parts Breakdown

    Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN 7,21 7,21 7,21 7,39 7,39 Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 39 Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN 2,23 Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 40 Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 41 Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN 14, 30 Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 42 Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN ITEM # PART # DESCRIPTION QTY. 12225 GASKET AUGER HOUSING HPS FEED SYSTEM 720110 EXHAUST BLOWER 16135 ASH PAN WELDMENT 16278 PANEL RIGHT REPLACEMENT KIT 16279 PANEL LEFT REPLACEMENT KIT 16280 PANEL BACK REPLACEMENT KIT 16281 TOP AND HOPPER WELDMENT LID REPLACEMENT KIT...
  • Page 43 Operator's Manual Serenity Pellet Stove ILLUSTRATED PARTS BREAKDOWN ITEM # PART # DESCRIPTION QTY. 16284 KIT HOPPER ASSEMBLY REPLACEMENT 21565 ROOM BLOWER REPLACEMENT KIT 720055 HOPPER LID SWITCH 720106 SENSOR TEMPERATURE 92 DEG C 720204 DOOR ASSEMBLY REPLACEMENT KIT 720107 AUGER MOTOR HPS &...
  • Page 44: Wiring Diagram

    Operator's Manual Serenity Pellet Stove WIRING DIAGRAM Electrical Plug Igniter Auger Motor Room Blower Exhaust Blower 120V~ AUGER CAPACITOR MICRO-SWITCH VACUUM / PRESSURE SWITCH FUSES THERMODISC 52C PROOF OF FIRE THERMOCOUPLE 30C ROOM TEMP 92C OVERTEMP Controller Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5...
  • Page 45: Efficiency

    Operator's Manual Serenity Pellet Stove Efficiency Efficiency is the measure of an appliance’s efficacy in • The efficient combustion of any fuel source is reliant converting energy input in the form of fuel to energy output on a proper balance of fuel and oxygen. This principle holds true for your Serenity™...
  • Page 46: Warranty

    SERENITY™ BY CASTLE™ PRODUCT WARRANTY: LIMITED ONE-YEAR WARRANTY Ardisam Inc., a manufacturing company, warrants this Castle Pellet stove to be free from defects in the material and workmanship for a period of one year. During that one-year period, Ardisam Inc. will, at their discretion, furnish parts to correct any defect caused by faulty material or workmanship.
  • Page 47 Manuel de l’utilisateur Poêle à granules Serenity Modéle 41278 ATTENTION NE PAS JETER! IMPORTANTES INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN INCLUSES. CONSERVEZ CES INSTRUCTIONS ET LAISSEZ CE MANUEL À TOUTE PERSONNE RESPONSABLE DE L’UTILISATION ET DU FONCTIONNEMENT. AVERTISSEMENT VEUILLEZ LIRE CE MANUEL EN ENTIER AVANT D’INSTALLER GAS/OIL ET D’UTILISER CET APPAREIL ATTENTION...
  • Page 48 Suivre avec attention toutes les instructions d’assemblage. • Entretenir le poêle conformément aux instructions et au calendrier figurant dans le manuel de l’utilisateur Castle. • S’assurer que quiconque utilise le poêle est familiarisé avec toutes les commandes et mesures de précaution.
  • Page 49 Manuel de l’utilisateur Poêle à granules Serenity AVERTISSEMENT AVERTISSEMENT POUR ÉCARTER LES RISQUES DE DÉGÂTS MATÉRIELS, DE BLESSURES CORPORELLES, VOIRE SURFACE CHAUDE! NE PAS TOUCHER! DANGER DE MORT, VEILLER À LIRE CE MANUEL EN ENTIER BRÛLURES GRAVES. VÊTEMENTS PEUVENT S’ENFLAMMER. LA VITRE ET LES AVANT D’INSTALLER ET D’UTILISER CET APPAREIL AUTRES SURFACES SONT CHAUDES DURANT LE DE CHAUFFAGE AUTONOME À...
  • Page 50 ET DOIT ÊTRE RESPECTÉ. S’ADRESSER À L’INSPECTEUR LA COMBUSTION DE TOUT COMBUSTIBLE NON EN BÂTIMENT LOCAL POUR OBTENIR TOUS LES PERMIS CERTIFIÉ PAR CASTLE PELLET STOVES DANS CE OU LES RÈGLES D’INSPECTION NÉCESSAIRES AVANT POÊLE A POUR EFFET D’ANNULER LA GARANTIE.
  • Page 51 POÊLE À GRANULES. DETERMINER SI UN PERMIS EST NÉCESSAIRE. LES PIÈCES EN MOUVEMENT DE CE POÊLE SONT LE POÊLE À GRANULES CASTLE PELLET STOVES EST ENTRAÎNÉES PAR DES MOTEURS ÉLECTRIQUES DE CONÇU POUR BRÛLER UNIQUEMENT DES COMBUSTIBLES COUPLE ÉLEVÉ. CES PIÈCES PEUVENT CAUSER DE EN GRANULES.
  • Page 52 Manuel de l’utilisateur Poêle à granules Serenity TABLE DES MATIÈRES TABLE DES MATIÈRES AVERTISSEMENTS ET MESURES DE PRÉCAUTION ..................................2-5 Table des matières ..............................................6 ENREGISTREMENT ET REGISTRE D’ENTRETIEN ....................................7 INTRODUCTION................................................8 Combustion de granules ............................................8 Fonctions de sécurité automatiques .........................................8 CARACTÉRISTIQUES ..............................................9 DÉBALLAGE ..................................................9 INSTALLATION ................................................
  • Page 53: Enregistrement Et Registre D'entretien

    Noter le numéro de modèle et le numéro de série dans l’espace prévu pour toujours les avoir à disposition. Complétez et envoyez par courrier postal la carte d’enregistrement trouvée dans le paquet de pièces ou effectuez l’enregistrement en ligne à www. castlepelletstoves.com. La garantie est valable uniquement si l’enregistrement dûment rempli est reçu par Castle dans les 30 jours après l’achat.
  • Page 54: Introduction

    Nous vous félicitons pour votre investissement dans la qualité. être régulièrement nettoyées et enlevées du poêle à Merci d’avoir acheté un poêle à granules Castle. Nous nous granules. Les scories forment une masse dure qui bloque sommes attachés à ce que ce poêle à granules réponde aux plus la circulation d’air à...
  • Page 55: Caractéristiques

    Ce poêle est équipé d’une vitre céramique de 5 mm. Remplacer bas de la palette qui fixent le poêle à la palette. la vitre uniquement par une vitre céramique de marque Castle Installez les quatre (4) pieds réglables au bas du poêle.
  • Page 56: Installation

    Manuel de l’utilisateur Poêle à granules Serenity INSTALLATION Il est recommandé de faire installer et entretenir le poêle par des AVERTISSEMENT professionnels agréés qui sont certifiés spécialistes des granules NFI par le National Fireplace Institute (NFI). LIRE CE MANUEL EN ENTIER AVANT D’INSTALLER Ce poêle doit être installé...
  • Page 57: Dégagements Jusqu'aux Matériaux Combustibles

    Manuel de l’utilisateur Poêle à granules Serenity Dégagements jusqu’aux matériaux combustibles REMARQUE : Ces distances sont les dégagements minimum jusqu’aux matériaux combustibles établis par le laboratoire d’essai de l’ASTM (VOIR FIGURES 3, 4, 5 et 6). 12,7 12,7 17,8 12,7 Figure 3 : Pose droite, évacuation à...
  • Page 58: Évacuation

    Manuel de l’utilisateur Poêle à granules Serenity Évacuation Avant de poser l’évacuation, consulter les spécifications et ATTENTION recommandations du fabricant de conduits pour toutes les installations d’évacuation. NE PAS RACCORDER CET APPAREIL À UN CONDUIT Les directives de pose suivantes doivent être respectées pour DE FUMÉE UTILISÉ...
  • Page 59: Dégagements Préconisés Pour La Sortie D'évacuation

    Manuel de l’utilisateur Poêle à granules Serenity Dégagements préconisés pour la sortie d’évacuation • L’évacuation du poêle doit déboucher sur l’extérieur du bâtiment. Les sorties horizontales doivent dépasser d’un minimum de 30 cm (12 po) du mur. Les sorties verticales doivent dépasser d’un minimum de 60 cm (24 po) de la surface du toit. En outre, tous les dégagements indiqués ci-dessous doivent être respectés.
  • Page 60 Manuel de l’utilisateur Poêle à granules Serenity Évacuation du poêle à granules (voir Figures 8 à 16) ATTENTION S’ASSURER QUE L’ÉVACUATION DU POÊLE À GRANULES 10 m (33 pi) (max.) EST CORRECTE. NE PAS POSER DE REGISTRE DE TIRAGE DANS LE SYSTÈME D’ÉVACUATION DE L’APPAREIL. 9 m (30 pi) UTILISER MANCHON...
  • Page 61: Raccordement D'air Extérieur

    REMARQUE : Les tuyaux de PVC ne sont PAS homologués et ne doivent JAMAIS être raccordés au poêle. ATTENTION CONSEIL PRATIQUE : L’admission d’air d’un poêle à granules Castle accepte des tuyaux et raccords d’échappement automobiles. L’UTILISATION DE VENTILATEURS D’EXTRACTION Si l’admission d’air est raccordée à l’extérieur, elle doit TELS QUE LES VENTILATEURS DE SALLE DE IMPÉRATIVEMENT se terminer par un coude vertical de 90...
  • Page 62 Manuel de l’utilisateur Poêle à granules Serenity EXEMPLES DE VENTILATION SIMPLE DU POÊLE ouverture matériau résistant à la chaleur admission d’air frais plancher Figure 10 : Pose droite — En dehors élévation verticale, sortie horizontale ouverture tuyau d’évacuation matériau résistant à la chaleur admission d’air frais propre-out plancher...
  • Page 63 Manuel de l’utilisateur Poêle à granules Serenity EXEMPLES DE VENTILATION COMPLEXE DU POÊLE Capote verticale 61 cm (24 po) minimum Mitre Abergement L’isolation doit maintenir le dégagement Le conduit doit Support/bouclier pare-feu de plafond maintenir le dégagement par rapport aux matériaux Conduit « L »...
  • Page 64 Manuel de l’utilisateur Poêle à granules Serenity ADAPTATION D’UNE CHEMINÉE DE CLASSE A Cheminée de classe A Mitre Abergement Une cheminée de Classe A doit maintenir les dégagements indiqués dans les instructions d’installation de la cheminée (habituellement 5 cm [2 po]) Support de plafond pour cheminée de Classe A Adaptateur conduit « L »...
  • Page 65 Manuel de l’utilisateur Poêle à granules Serenity POÊLE POUR ÂTRE DE CHEMINÉE EN MAÇONNERIE Capote verticale Conduit « L » Couvercle (non combustible) Sceller le couvercle Mitre avec du silicone Conduit flexible « L » 7,5 cm (3 po) Linteau 15 cm (6 po) min. L’air extérieur peut être aspiré...
  • Page 66 Manuel de l’utilisateur Poêle à granules Serenity POÊLE POUR ÂTRE DE CHEMINÉE À DÉGAGEMENT ZÉRO (MÉTALLIQUE) Couvercle (non combustible) Capote verticale Sceller le couvercle avec du silicone Mitre Conduit « L » Conduit flexible « L » 7,5 cm (3 po) 15 cm (6 po) min.
  • Page 67 Manuel de l’utilisateur Poêle à granules Serenity CHEMINÉE EN MAÇONNERIE SEULE Capote verticale Conduit « L » Couvercle (non combustible) Mitre Sceller le couvercle avec du silicone Section de conduit « L » Sections de conduit « L » Dégagement du conduit* Regard de nettoyage 15 cm (6 po) min.
  • Page 68: Comprendre Le Poêle

    10. Touche de défilement bas - Permet de faire défiler le menu affiché vers le bas. Le poêle à granules Castle comporte un système d’alimentation 11. Touche Entrée - Permet d’ajuster et de sélectionner des de combustible à vis sans fin verticale commandée par un circuit données à...
  • Page 69: Écran D'affichage Principal De La Commande

    Manuel de l’utilisateur Poêle à granules Serenity ÉCRAN D’AFFICHAGE PRINCIPAL DE LA COMMANDE Figure 19a : Écran principal de la commande Figure 19a : Écran d’affichage principal de la commande 1. Mode de chauffage : Affiche le mode d’exploitation - manuel, température ou hebdomadaire. 2.
  • Page 70: Écran D'affichage D'état Des Composants

    Manuel de l’utilisateur Poêle à granules Serenity ÉCRAN D’AFFICHAGE D’ÉTAT DES COMPOSANTS Figure 19b : Écran d’état des composants Figure 19b : Écran d’affichage d’état des composants 1. Indicateur d’état marche/arrêt : Indique si le poêle est en marche (ON) et en mode opérationnel ou s’il est en cours de mise à...
  • Page 71: Avant Utilisation

    à l’intérieur du poêle. Avant de démarrer le poêle Castle, il convient de déterminer dans quel mode on souhaite le faire fonctionner. Le Serenity comporte trois modes d’exploitation :...
  • Page 72 Manuel de l’utilisateur Poêle à granules Serenity température ambiante souhaitée. Le poêle ne s’éteint pas complètement si la température ambiante souhaitée est dépassée. Cela convient à la majorité des utilisateurs et présente l’avantage de préserver le cycle de vie de l’allumeur.
  • Page 73: Fonctionnement

    Manuel de l’utilisateur Poêle à granules Serenity FONCTIONNEMENT Après avoir choisi le mode de fonctionnement du poêle, appuyer AVERTISSEMENT sur la touche de marche/arrêt (4, Fig. 17) pour lancer le cycle d’allumage du poêle. JAMAIS ÉTEINDRE POÊLE Démarrage DÉBRANCHANT DE LA PRISE ÉLECTRIQUE. NE JAMAIS ÉTEINDRE LE POÊLE EN METTANT Lorsque le poêle se met en marche, l’indicateur d’allumage et L’INTERRUPTEUR D’ALIMENTATION PRINCIPAL AU...
  • Page 74: Configuration Des Autres Données Sur La Commande

    Manuel de l’utilisateur Poêle à granules Serenity CALENDRIER HEBDOMADAIRE , le cas 2. Dans l’écran du REMARQUE : Si un calendrier particulier a été défini pour un échéant, régler les heures de marche du dimanche (« Sun. »). jour donné et qu’on souhaite l’appliquer aux ENTRÉE pour mettre les heures en surbrillance puis autres jours de la semaine, aller à...
  • Page 75 Manuel de l’utilisateur Poêle à granules Serenity Réglage de la tension du ventilateur Pour régler la tension du ventilateur : ENTRÉE enfoncée. Le menu « SET DATA » 1. Tenir la touche La tension du ventilateur (qui contrôle le ventilateur d’air (configuration de données) s’affiche à l’écran. ambiant) peut être augmentée ou diminuée pour chaque niveau DÉFILEMENT BAS 2.
  • Page 76 Manuel de l’utilisateur Poêle à granules Serenity Réglage de la tension d’évacuation sélectionner le niveau de chauffage. Appuyer sur ENTRÉE pour valider la sélection du niveau de chauffage. REMARQUE IMPORTANTE : REMARQUE : Les niveaux de chauffage sont identifiés par AJUSTER LE VOLET DE DÉBIT D’AIR AVANT H01 (niveau de chauffage 1) à...
  • Page 77: Diagnostic

    DIAGNOSTIC POF : (détection de flamme) Indique si le détecteur de flamme est activé. La commande du poêle Castle est équipée d’une option de diagnostic embarquée qui permet de contrôler certains éléments RT : (température ambiante) Indique la température du poêle.
  • Page 78: Entretien

    Contrôler régulièrement les joints sur le pourtour de la vitre. Changer tout joint usé, effiloché ou écrasé. Remplacer une vitre brisée uniquement par une vitre céramique haute température, disponible auprès de Castle Pellet Stoves. VOIR FIGURE 31. Figure 30 : Nettoyage de la boîte à feu Émissions du poêle Les émissions du poêle doivent être contrôlées visuellement...
  • Page 79: Entretien Quotidien

    Manuel de l’utilisateur Poêle à granules Serenity Entretien quotidien Les surfaces du poêle peuvent être chaudes. Toujours porter un AVERTISSEMENT gant protecteur, même si le poêle est froid au toucher. Veiller à LES SURFACES CHAUDES PEUVENT PROVOQUER DES éteindre le poêle et le laisser refroidir pendant une heure avant BRÛLURES.
  • Page 80 Manuel de l’utilisateur Poêle à granules Serenity En plus des tâches d’entretien quotidien, nettoyer l’intérieur de la boîte à feu avec un aspirateur à cendres. Sortir la boîte à feu du porte-boîte et passer l’aspirateur en dessous. Veille à bien éliminer toutes les cendres de l’entrée du tube d’allumeur.
  • Page 81: Dépannage Et Réparation

    Poêle à granules Serenity DÉPANNAGE ET RÉPARATION AVERTISSEMENT Chez Castle, nous intégrons la qualité et la durabilité dans la conception de nos produits; mais toute la conception soignée et tout l’entretien attentionné ne sauraient garantir une existence LORS DE TOUTE OPÉRATION D’ENTRETIEN totalement exempte de réparation du poêle.
  • Page 82: Guide De Dépannage

    Manuel de l’utilisateur Poêle à granules Serenity GUIDE DE DÉPANNAGE AVERTISSEMENT AVERTISSEMENT NE JAMAIS TOUCHER NI EFFECTUER L’ENTRETIEN DE LA VIS SANS FIN ALORS QUE LE POÊLE EST DÉBRANCHER LE POÊLE ET LE LAISSER REFROIDIR BRANCHÉ. AVANT TOUTE OPÉRATION D’ENTRETIEN. LES PIÈCES CHAUDES PEUVENT PROVOQUER DES BRÛLURES.
  • Page 83 Manuel de l’utilisateur Poêle à granules Serenity PROBLÈME CAUSE SOLUTION Pas l’alimentation en combustible, La vis sans fin est obstruée Sortir la vis sans fin de son logement et nettoyer d’abord présence de signal de dépression l’obstruction. La vis sans fin ne fonctionne pas et de couvercle sur la commande.
  • Page 84: Illustration Des Pièces Détachées

    Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES 7,21 7,21 7,21 7,39 7,39 Voir les pièces détachées en ligne à www.castlestoves.com ou composer le 800-345-6007 L-V 8h-17h...
  • Page 85 Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES 2,23 Voir les pièces détachées en ligne à www.castlestoves.com ou composer le 800-345-6007 L-V 8h-17h...
  • Page 86 Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES Voir les pièces détachées en ligne à www.castlestoves.com ou composer le 800-345-6007 L-V 8h-17h...
  • Page 87 Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES 14, 30 Voir les pièces détachées en ligne à www.castlestoves.com ou composer le 800-345-6007 L-V 8h-17h...
  • Page 88 Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES REPÈRE RÉF. DESCRIPTION QTÉ 12225 JOINT DE LOGEMENT DE VIS SANS FIN SYSTÈME ALIM HPS 720110 VENTILATEUR DE D’ÉVACUATION 16135 CENDRIER 16278 KIT PANNEAU DROIT DE RECHANGE 16279 KIT PANNEAU GAUCHE DE RECHANGE 16280 KIT PANNEAU ARRIÈRE DE RECHANGE 16281...
  • Page 89 Manuel de l’utilisateur Poêle à granules Serenity ILLUSTRATION DES PIÈCES DÉTACHÉES 16284 KIT TRÉMIE DE RECHANGE 21565 KIT VENTILATEUR DE CONVECTION DE RECHANGE 720055 CONTACTEUR DE COUVERCLE DE TRÉMIE 720106 SONDE DE TEMPÉRATURE 92 °C 720204 KIT PANNEAU DE PORTE DE RECHANGE 720107 MOTEUR DE VIS SANS FIN HPS &...
  • Page 90: Schéma De Câblage

    Manuel de l’utilisateur Poêle à granules Serenity SCHÉMA DE CÂBLAGE Prise Électrique Allumeur Moteur Vis Sans Fin Ventilateur Ambiant Ventilateur D’ Evacuation 120V~ BLEU CONDEN- SATEUR MICRORUPTEUR TARIÈRE INTERRUPTEUR DE VIDE / PRESSION FUSIBLES THERMODISQUE 52C PREUVE DE FEU THERMOCOUPLE 30C TEMPÉRATURE AMBIANTE 92C DESSUS DE LA...
  • Page 91: Rendement

    Manuel de l’utilisateur Poêle à granules Serenity Rendement Le rendement est la mesure de l’efficacité d’un appareil à supérieure), notamment parce qu’ils ont une faible transformer une entrée d’énergie fournie sous forme de carburant teneur en humidité. en une sortie d’énergie sous forme de chaleur. Les incohérences •...
  • Page 92: Garantie

    GARANTIE PRODUIT SERENITY™ DE CASTLE™ : GARANTIE LIMITÉE UN AN Ardisam Inc., une entreprise de fabrication, garantit que ce poêle à granules Castle est exempt de vices de matériaux et de fabrication pendant une durée d’un an. Pendant cette durée d’un an, Ardisam Inc., à son entière discrétion, fournira les pièces nécessaires pour corriger toute défaillance résultant de vices de matériaux ou de fabrication.