MAINTENANCE OF BATTERY
1.
Check electrolyte level periodically (at least every
two weeks). Keep the level to the split rings. Use
only distilled water or a good quality drinking
water. Never add acid or any other chemicals to
the battery after initial activation.
2.
The battery should be checked with a hydrometer
after every 25 hours of operation. If the specific
gravity is less than 1.225, the battery should be
recharged. Maximum charge rate 5 amps.
COMMON CAUSES FOR BATTERY FAILURE
1.
Overcharging
2.
Undercharging
3.
Lack of water
4.
Loose hold downs and/or corroded connections
5.
Excessive loads
6.
Battery electrolyte substitutes
7.
Freezing of electrolyte
3.
Coat the terminals and exposed wire with a thin
coat of grease or petroleum jelly for longer ser¬
vice and protection against corrosion.
4. The battery should be kept clean. Any deposits
of acid should be neutralized with baking soda
and water. Be careful not to get this solution in
the cells.
NOTE
These failures do not constitute warranty.
BATTERY REMOVAL OR INSTALLATION
5. Avoid tipping the battery. Even a '■sealed" battery
will leak electrolyte when tipped.
STORAGE OF THE BATTERY
1.
When storing battery for extended periods,
disconnect battery cables.
Removing battery
from unit is recommended.
2.
Keep the exterior of the battery clean, especially
the top. A dirty battery must be stored with a full
charge. A dirty battery will discharge itself.
3.
Check the battery with a hydrometer. The battery
must be stored with a full charge. A discharged
battery will freeze.
WARNING
When removing the battery, follow this order
of disassembly to prevent your wrench from
shorting against the frame.
1.
Remove the Negative cable.
2.
Remove the Positive cable.
To Install a battery:
1.
Attach the Positive cable.
2. Attach the Negative cable.
Specific Gravity
1.265
1.250
1.200
1.150
1.100
NOTE
All batteries discharge during storage.
4. Recharge battery whenever the specific gravity is
less than 1.225, before returning to service or
every two months, whichever comes first.
1.
Attach the first jumper cable from the positive ter¬
minal of the good battery to the positive terminal
of the dead battery.
2.
Attach the second jumper cable from the negative
terminal of the good battery to the FRAME OF
THE UNIT WITH THE DEAD BATTERY.