Summary of Contents for Feig Electronic ID PAD74-U
Page 1
IDENTIFICATION INSTALLATION ID PAD74-U PAD Reader with USB Interface M30521-1e-ID-B...
Page 2
FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health.
Page 3
IDENTIFICATION ID PAD74-U Safety Instructions ► The device may only be used for the intended purpose designed by for the manufacturer. ► The operation manual should be conveniently kept available at all times for each user. ► Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
Content ID PAD74-U PAD Reader with USB-Interface Scope of delivery ....................... 5 Available Software-Tools, USB drivers and Firmware ............ 6 Difference between ID PAD74-U and ID CPR74-CUSB ............ 6 Dimension Installation Table top mounting ......................9 Under table mounting ......................9 Commissioning DC Power supply ......................
ID PAD74-U 1 ID PAD74-U PAD Reader with USB-Interface • The ID PAD74-U is an RFID PAD reader for contactless data exchange with passive transponders and combines a reader and an antenna in one housing. • The compact format allows the PAD74-U to be positioning "on" and "under" any nonmetallic mounting or table top.
A firmware update tool and an xml firmware file are available for firmware updates. 1.3 Difference between ID PAD74-U and ID CPR74-CUSB The reader module installed in the ID PAD74-U does not support all commands and functions that are available in the reader module ID CPR74-CUSB.
IDENTIFICATION ID PAD74-U 3 Installation • The PAD74-U is designed for operation on a non metallic, flat surface (e.g. table) or for under table mounting (non metallic) indoors. • Device connection via USB cable (2.3 m) • The cable length must not be changed.
Page 10
IDENTIFICATION ID PAD74-U • Remove rubber feet • Use drilling pattern, (see Fig. 3) • The predrilled holes (2.0 mm) are located under the rubber feet. Figure 7: Predrilled holes (2.0 mm) Figure 6: Remove rubber feet • Drill out factory holes from 2.0 mm...
Page 11
IDENTIFICATION ID PAD74-U • The antenna is aligned with the top (front foil side) facing up and mounted. Figure 10: Under table mounting NOTE: • Before mounting, the rubber feet must be removed. • Use drilling pattern • Drilling holes at locations other than provided in drilling pattern, will destroy the electronics.
The standard reader configuration can be adapted to the application using the ISOStart service software from version 11.07.xx or higher • The service software can be found on the download area of FEIG ELECTRONIC GmbH at https://www.feig.de/en/ 4.1 DC Power supply •...
5.1 Declaration of Conformity (CE), (UKCA) CE Declaration of Conformity Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID PAD240-U is in compliance with directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.feig.de/en/service/eu-declarations-of-conformity/...
IDENTIFICATION ID PAD74-U 6 Technical Data Mechanical Data Wight: approx. 0,5 kg Dimension: (240 x 180 x 13) mm (L x W x H) (9,45 x 7,08 x 0,51) in3 Front cover: Insensitive surface Housing: Protection class: IP30 Color: RAL 9003 (white)