OPERATING and MAINTENANCE INSTRUCTIONS
R171SUA10
R171S1828
R171SUA10240
R171S1828240
R171SUA20
R171S1856
R171SUA20240
R171S1856240
Note: The above model numbers are basic models. They may be followed by letters: M, L, D or
ending with S, Z and/or CAN.

HOW TO INSTALL THE CABINET:

1.
Remove all packing material from inside the
cabinet.
2.
INSTALL ALL ANGLES
TURNED ON
3.
Allow enough clearance around cabinet for air
fl ow.

HOW TO OPERATE:

1.
Plug cord into proper wall outlet.
2.
Turn the power switch to "ON". Light will come
on and compressor will start.
Listen closely for the compressor. It will be slightly
loud at fi rst, then quiet down.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
for Cres Cor Refrigerated Cabinets,
Model R-171-S Series
Model No.
Volts
BEFORE UNIT IS
Amps
Hertz
120
7.8
240
3.7
120
8.6
240
4.2
CONTROL PANEL
HOW TO OPERATE (Continued):
If you do not hear the compressor running, turn power
switch to "OFF" right away. See "Troubleshooting"
(page 3).
3. Pre-chill the cabinet for approximately 40 minutes
or until the temperature reaches approximately
38°F. Load the food.
DO NOT PUT HOT FOOD INTO COLD
CABINET!
TO SHUT UNIT OFF:
Turn power switch to "OFF".
Series R-171-S
Refrigerated Cabinets
Rev. 3 (10/06)
Phase
NEMA
60
1
5-15P
60
1
6-15P
60
1
5-15P
60
1
6-15P
FL-2314
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R171S1828 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cres Cor R171S1828

  • Page 1 TO SHUT UNIT OFF: on and compressor will start. Turn power switch to “OFF”. Listen closely for the compressor. It will be slightly loud at fi rst, then quiet down. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 2 GREASE, OIL stainless steel. directions. (Stainless Steel) 1. Swab or wipe with cloth. HARD WATER Vinegar 2. Rinse and dry. SPOTS & SCALE *Mild detergents include soaps and non-abrasive cleaners. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 3 1. Thermostat is pre-set at approximately 38°F (3.8°C). Temperature adjustment can only be made by a Service Agency. 2 For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400). Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 4 Thermometer Kit 5238-035-K 5238-035-K Thermostat (cold control) 0854-043-K 0854-043-K Valve, Thermal Exp. (R171SUA10, 1828) 0854-042-K1 0854-042-K1 Valve, Thermal Exp. (R171SUA20, 1856) 0854-042-K2 0854-042-K2 Vent Fan (R171SUA20, 1856 ONLY) 0769-045-K 0769-029-K Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...