Cres Cor KC-UA-11 Operating And Maintenance Instructions Manual

Cres Cor KC-UA-11 Operating And Maintenance Instructions Manual

Refrigerated cabinet

Advertisement

Quick Links

5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
for Cres Cor Refrigerated Cabinet, Models KCUA11 & KCUA11H
Cabinet model number:
Cabinet serial number:
Authorized Service Agency:
Ph:
Keep this manual for future reference.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
KC-UA-11
KC-UA-11H
Fax:
KoldCube
3
Refrigerated Cabinet
Page 1 of 9
Rev. 1 (7/19)
FL-2379

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KC-UA-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cres Cor KC-UA-11

  • Page 1 OPERATING and MAINTENANCE INSTRUCTIONS for Cres Cor Refrigerated Cabinet, Models KCUA11 & KCUA11H KC-UA-11 KC-UA-11H Cabinet model number: Cabinet serial number: Authorized Service Agency: Fax: Keep this manual for future reference. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 2: Initial Setup

    Internal controls will self-regulate the temperature CRES COR PART. USING A DIFFERENT – no adjustment is necessary. BATTERY CHARGER VOIDS WARRANTY AND COULD DAMAGE EQUIPMENT OR (Continued on Page 3) CREATE A POTENTIALLY HAZARDOUS SITUATION. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 3 10%. It is OK to leave unit plugged in after it has reached 100% charge – battery charger will settle on a voltage that is safe to leave for a period of time. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 4: Maintenance Instructions

    GREASE, OIL stainless steel. directions. (Stainless Steel) 1. Swab or wipe with cloth. HARD WATER Vinegar 2. Rinse and dry. SPOTS & SCALE *Mild detergents include soaps and non-abrasive cleaners. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 5: Technical Specifications

    NOTE: When servicing unit, refrigerant MUST be replaced ONLY with that listed on spec plate of unit. Do not attempt to retrofit a different refrigerant than that which came in the unit from the factory. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 6: Troubleshooting Guide

    3b. Replace. 4. Refrigerant loss. 4a. Leak. 4a. Check system for leaks, recharge. NOTES: 1. For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400). Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 7: Replacement Parts

    6 Accumulator 0854-044 0854-044 14 Hinge kit 0519-110-K 0519-110-K 7 Circuit breaker 3A 0807-167 0807-167 15 Door assembly 1221-685-IN 1221-685-IN 8 Circuit breaker 15A 0807-168 0807-168 16 Door gasket 0861-300 0861-300 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 8 25 Drier 0858-008 0858-008 PV connector - 0807-194 0807-194 26 Drain tube 0913-148 0913-148 20W solar panel 7037-019 7037-019 27 Battery (ea) 7037-016 7037-016 Bluetooth dongle, battery monitor 7037-018 7037-018 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 9: Wiring Diagram

    KoldCube FL-2379 Refrigerated Cabinet Page 9 of 9 Rev. 1 (7/19) 5925 Heisley Road • Mentor, OH 44060-1833 WIRING DIAGRAM Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...