HYDROGEN SULPHIDE SENSOR
User Guide for SRAQ-G215
Product Description
The SRAQ-G215 gas sensor detects the presence and concentration of Hydrogen sulfide and other sulfur based organic vapors. Integrated circuitry
produces a non-linear voltage signal corresponding to the gas concentration. With a detection range of 1 to 200 ppm, the SRAQ-G215 sensor module
can be integrated into portable H
Features
Features MQ136 sensing element
High sensitivity and selectivity
Adjustable sensitivity
Detection range 1  200ppm
Analog output
Wall or DIN rail mountable
Applications
Outdoor air quality monitoring
Factory settings
Commercial sites - School, hospitals etc.
Smart buildings
Other areas where H
S is a concern
2
Thank you for choosing L-com product. To ensure safe, accurate performance and product longevity, please take a moment to familiarize yourself
with this manual before powering the device. Please keep it handy for future reference. In case of any questions regarding the installation or use of
product, please call us at 800.341.5266.
Reach out to us at customerservice@l-com.com and visit our website at www.l-com.com
S detectors or other air quality monitoring equipment.
2
1

Advertisement

loading

Summary of Contents for Infinite L-com SRAQ-G215

  • Page 1 HYDROGEN SULPHIDE SENSOR User Guide for SRAQ-G215 Product Description The SRAQ-G215 gas sensor detects the presence and concentration of Hydrogen sulfide and other sulfur based organic vapors. Integrated circuitry produces a non-linear voltage signal corresponding to the gas concentration. With a detection range of 1 to 200 ppm, the SRAQ-G215 sensor module can be integrated into portable H S detectors or other air quality monitoring equipment.
  • Page 2 Technical Parameters 1  200 PPM Detection Range Measured Gas Working Voltage 24 VDC ± 0.2 V Working Current <150 mA Output Method 0  10 V (Non-linear) Response Time ≤1 sec Recovery Time ≤30 sec Working Temperature -10~50 °C Working Humidity <95% RH (Non condensing) Preheat Time...
  • Page 3 Electrical Diagram 24V and GND are the power interface, D1 is the power indicator. Aout is the analog output interface, VR2 is the signal trimmer potentiometer. VR1 is the magnification (the output of 0-5V and 0-10V can be adjusted freely through this potentiometer). The load resistance of the sensor composed of R7 and RP2 potentiometer is in parallel relationship (can be changed by user).